FAST PROGRAMMING GUIDE

Function code
Function description
00...99
Authorisation and allocation of access codes (100 codes)
A A
Delete a code
A0
Master code programming
A1
Free access programming (trade)
A2
Relay activation timing programming
A3
Change code length from 4 to 6 digits
A4
Enable/disable exit B pushbutton
A5
Enable/disable possibility that users may change their own codes
A6
Programmimg auxiliary output alarm or incidents alert function
(designated 'AUX')
A7
Programming auxiliar output activation timing
A8
Programmimg open door sensor timing
A9
Delete all codes
Sequence of codes to be entered:
+
Master Code
(1480)
Pag 12
00...99
+
Access code (4 to 6 digits)
Memory position
00...99: Memory position of code
+
AA
to be deleted
New Master Code
A0
+
A1
New Free Access Code
+
00:
A2
+
01..99
+
A3
4, 5 or 6
1: Pushbutton enabled
A4
+
0: Pushbutton disabled
1: Enabled
A5
+
0: Disabled
1: Enabled
A6
+
0: Disabled
00: Loudspeaker alarm tone
A7
+
01..99 sec. (AUX activated 125 mA)
00: Disabled
+
A8
01..99: Enabled (01 to 99 sec.)
A9
Master Code (1480)
+
Bistable mode
(01 to 99 seconds)
Example
1480 02 1144
1480 AA 02
1480 A0 1234
1480 A9 5678
1480 A2 00
1480 A2 05
1480 A3 4
1480 A4 1
1480 A4 0
1480 A5 1
1480 A5 0
1480 A6 1
1480 A6 0
1480 A7 00
1480 A7 12
1480 A8 00
1480 A5 15
1480 A9 1480