DESCRIPTION OF THE UNIT
OPERATING THE UNIT
Before waxing up place a protective cap (3) in the
spool opening (1) to catch any drops of wax and
1
Coil opening for instruments
keep the unit clean. Hold the modelling instrument
in the spool opening (1) to heat it. Only metallic
2
LED display for operating status
objects are heated. The heating coil is activated by
3
Protective cap
an integrated sensor that only reacts to instruments
containing steel. Activation is indicated by the illumi-
4
ON/OFF switch
nated red LED display (2). The instrument is heated
just as quickly as with a Bunsen burner and larger
5
Mains connection
instruments are heated even more quickly.
6
Fan cooler
Caution: A metallic object can become red hot if
left for a longer period in the coil opening. Risk of
burns! Do not put other metallic objects near the
DESCRIPTION OF THE PRODUCT
coil as this can interfere with the sensor function!
The Noflame
®
Plus is suitable for most types of
The Noflame
waxing up and eliminates the need for conventional
fan cooler (6) to protect the heating coil from over-
Bunsen burners in the laboratory as well as alco-
heating. The fan cooler automatically switches on if
hol/gas burners in the dental practice by using the
there is an increase in temperature inside the unit.
tried and tested induction technique. It heats the
instrument just as quickly as a Bunsen burner and
heats larger instruments even more quickly. As
SERVICING
®
Noflame
Plus only heats instruments containing
Like most AmannGirrbach units, Noflame
steel, it is impossible to burn oneself on the exterior
designed to be maintenance-free. Simply ensure that
or inside the unit. Another advantage of the induction
the unit is kept clean. The protective caps have to be
technique is that there is no carbon residue left on
used to keep the unit clean and have to be replaced
the modelling instrument during heating, which pre-
when they become heavily contaminated. Also, the
vents contamination of the modelling wax. A plastic
ventilation slits have to not be covered to ensure
protective cap keeps the coil opening clean. Unlike a
that the fan cooler functions perfectly.
Bunsen burner, the Noflame
®
Plus does not require a
gas supply and technicians can continue to use their
normal modelling instruments in the usual manner.
INSTALLATION
Check the unit immediately after removal from the
packaging for possible damage caused in transit. If
there is any damage, inform the supplier immediately.
The unit is supplied ready for operation. Check that
the voltage given on the rating plate on the bottom
of the unit corresponds to the mains voltage. If you
are unsure about the mains voltage, check with an
electrician.
To install the unit simply plug in the mains cable at
the back (5) and switch the ON/OFF switch (4) to
ON. The unit is now in stand-by mode. This is indica-
ted by the illuminated green LED display (2) on the
front. The unit does not require the same safety
precautions as Bunsen burners as maximum consi-
deration was given to safety aspects during its
®
development. Place the Noflame
Plus in a position
comfortable for working.
6
Technical data:
Length/Width/Height:
Weight:
Power supply:
Output:
Protection:
Accessories/Components:
Order No.:
116210
Protective caps (10 caps)
342040
Modelling instrument Noflame, PKT1
342050
Modelling instrument Noflame, LeCron
®
Plus has an integrated, quiet-running
Packing list:
Order No.:
116250
Noflame
2 Protective caps
Mains cable
Instructions for use
Guarantee card
®
Plus is
ERRORS
The LED display (2) also indicates errors. The follo-
wing possible errors are indicated:
LED display:
Red flashes quickly
(0,2 second intervals)
Red flashes
(0,5 second intervals)
Red flashes slowly
(1 second intervals)
!
SAFETY PRECAUTION:
195 x 82 x 85 mm
600 g
230V/50Hz
TheNoflame
®
Plus was developed for use in the
130 W
dental sector. The instructions for use should be
IP20
adhered to during installation and operation. The
manufacturer does not accept liability for damages
arising from any other use or improper handling. In
addition, if the intended application is not listed in
the user's manual, the user is obliged to check
personally in advance that the unit is suitable for
this purpose.
• Only use Noflame
®
Plus indoor!
• Do not clean the unit with liquids containing
solvents!
• Keep the ventilation slits clean!
®
Plus
• Do not leave the modelling instrument
unattended in the coil opening!
• Always have repairs carried out by authorised
specialists!
• Always use original accessories or replace
ment components!
• The electromagnetic radiation of
Noflame
®
PLUS at a distance of 30cm is below
the limit values according to ICNIRP.
Cause of error:
Remedy:
Sensor interference (instrument
Remove the object from the coil ope-
or object containing steel is in
ning and cancel the error by switching
the coil opening for more than 6
the unit OFF/ON (4).
pulse cycles)
Sensor defect
Contact customer services!
Fan cooler blocked
Check the fan cooler and remove any
objects blocking the ventilation slits.
Cancel by switching the unit OFF/ON
(4).
Fan cooler faulty
Contact customer services!
Overheating inside the unit
Switch off the unit and allow it to cool!
Switch it on again after a few minutes.
If the error persists, contact customer
services.
GB