RX ONLY CAUTION: U.S. Federal law restricts this device to sale by or on the order of a dentist.
WARNING
• TO PREVENT ELECTRIC SHOCK Do not unplug the AC Adaptor with wet hands.
• TO PREVENT ELECTRIC SHOCK Be sure to avoid water on the Control Unit.
• TO PREVENT ELECTRIC SHOCK Do not touch the handpiece backend electrical connections.
• TO PREVENT ELECTRIC SHOCK Use an electrical outlet that is grounded.
• If you feel any abnormality such as heat generation or abnormal noise prior or during the use of the unit, stop using it immediately.
• This product is Medical Electrical Equipment Electromagetic Compatible (EMC). As described in the accompanying documentation.
• Portable and mobile RF (Radio Frequency) communications equipment can affect Electrical Medical equipment. Do not use RF equipment in
close proximity to the product.
• When installing the product, provide space of approximately 10cm (4 inches) around the Control Unit for easy access to the inlet and the AC
Adaptor.
• USE ONLY NSK Tips when using the Brasseler Forza V3 Ultrasonic scaler. Problems such as damage and failure resulting from use of Non-NSK
Tips are not included in the warranty. The following are the possible failures that could happen when using Non-NSK Tips:
- Vibration failure caused by using non conforming screws.
- Patient accidental ingestion of broken Tips.
- Damage to the threading of the handpiece.
• You must use the Tip within the power range described on the Tip-Power Guide. If you use it out of the power range, the Tip might break or
damage the operative site.
• When operating the product always consider the safety of the patient.
• Use by medical professional, such as doctor or dental hygienist, is intended.
• Check the vibration outside the patient's oral cavity before use. If any abnormalities are found, stop using immediately and contact Brasseler USA.
• Do not drop, hit, or subject Control Unit/Handpiece to excessive shock.
• To prevent possible tooth plane damage and handpiece overheating, always use with suffi cient water.
• Do not sterilize by ultraviolet light. Handpiece could discolor.
• Sterilize the Tip, Handpiece,Tip Holder, Tip Cover S and Tip Wrench by autoclaving. Wipe the Control Unit, Tip Holder, Tip, AC Adaptor, Foot
Control and Handpiece Cord including the cover with alcohol soaked cotton.
• If chemical, solvent or antiseptic solution is deposited on this product, immediately wipe it away. Discoloration or deformation may occur if not
removed.
• Do not disassemble or alter the handpiece/Control Unit.
• Keep away from patients with cardiac pacemakers.
• Keep away from explosive substances and fl ammable materials. Do not use on patients anesthetized under Nitrous oxide.
• This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information.
• The use of ACCESSORIES, transducers and cables other than those specifi ed, with the exception of transducers and cables sold by the manufacturer
of this product as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of this product.
• This product should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, this product should be
observed to verify normal operation in the confi guration in which it will be used.
• If any water drops remain on the handpiece or handpiece cord after autoclaving, wipe them off. Staining may result if not removed.
• User judgement is required when using this product.
• Eye damage may result if the LED is stared directly into. Do not look into or turn it to the eyes of the patient.
CAUTION
• During operation, high frequency oscillations in the handpiece and handpiece cord may affect computer and LAN Noise may be heard during
operation near a radio receiver.
• Be sure to turn off the Power/Volume Knob after use. Remove the AC Adaptor and water inside of the Control Unit before storage.
• Users are responsible for operational control, maintenance and inspection.
• Clean/sterilize the product immediately after using it. Then store it. Leaving it non-sterile might lead to failure.
• When you have not used the product for an extended period of time and use it again, check the operation before use.
• When abnormalities are found with a Control Unit and /or an AC adaptor, pull the AC adaptor from AC Outlet immediately.
• This product does not consider patient's age (except infants), gender, weight or nationality.
• No special training is required for this device.
• Applied parts for patient and/or operator are Tip and Handpiece.
• Tip is article of consumption. We recommend periodical replacement. About time of replacement, check the Tip Card.
• Additional Tips and accessories are available for order in the Brasseler USA catalog.
2