The Following Must Be Observed - clage MCX Série Instructions D'utilisation Et D'installation

Masquer les pouces Voir aussi pour MCX Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
MCX 3..7 SMARTRONIC

6 The following must be observed

The heater is installed as shown in the immediate vicinity of the outlet in a frost-free room. We
guarantee trouble-free operation only if CLAGE fittings and accessories are used. Note the fol-
lowing during installation:
EN
• Installation must comply with DIN VDE 0100 and EN 806 and with the statutory regulations
of the country and the provisions of the local electricity and water supply company.
• Check technical data and the information on the rating plate under the cover ("Removing
the cover", 29).
• Ensure that all accessories are removed from the packing materials.
• Easy access to the appliance shall be guaranteed at all times. An external shut-off valve has
to be installed.
• Thoroughly rinse the water pipes before connection.
• Optimum operation is ensured at a water flow pressure of 0.2 to 0.4 MPa (2–4 bar). The
appliance must not be subjected to pressure exceeding 1 MPa (10 bar).
• For safe operation of this instantaneous water heater, a non return valve is not required. If,
nevertheless, a non return valve has to be installed, it may be placed in the cold water inlet
line before the instantaneous water heater or in the hot water outlet line behind the instan-
taneous water heater.
®