Télécharger Imprimer la page

Pentair JUNG PUMPEN BAUFIX 100 3 Instructions De Service page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
You have purchased a product made by JUNG
PUMPEN and with it, therefore, also excel-
lent quality and service. Secure this service
by carrying out the installation works in ac-
cordance with the instructions, so that our
product can perform its task to your complete
satisfaction. Please remember that damage
caused by incorrect installation or handling
will adversely affect the guarantee.
Therefore please adhere to the instructions in
this manual!
As with all electrical devices, this product
can also fail to operate due to an interruption
in the electricity supply or due to a techni-
cal defect. If this could result in damage, a
mains-independent alarm system must be
installed. Depending on the application, you
may also wish to install an emergency power
generator, or a second system as a back-up.
SAFETY
INSTRUCTIONS
This instruction manual contains essential
information that must be observed during
installation, operation and servicing. It is
therefore important that the installer and
the responsible technician/operator read this
instruction manual before the equipment is
installed and put into operation. The manual
must always be available at the location
where the pump or the plant is installed.
Failure to observe the safety instructions can
lead to the loss of all indemnity.
In this instruction manual, safety information
is distinctly labelled with particular symbols.
Disregarding this information can be danger-
ous.
General danger to people
Warning of electrical voltage
ATTENTION!
Danger to equipment and operation
6
Qualification and training of
personnel
All personnel involved with the operation,
servicing, inspection and installation of the
equipment must be suitably qualified for this
work and must have studied the instruction
manual in depth to ensure that they are suf-
ficiently conversant with its contents. The su-
pervision, competence and areas of respon-
sibility of the personnel must be precisely
regulated by the operator. If the personnel do
not have the necessary skills, they must be
instructed and trained accordingly.
Safety-conscious working
The safety instructions in this instruction
manual, the existing national regulations
regarding accident prevention, and any inter-
nal working, operating and safety regulations
must be adhered to.
Safety instructions for the
operator/user
All legal regulations, local directives and
safety regulations must be adhered to.
The possibility of danger due to electrical en-
ergy must be prevented.
Leakages of dangerous (e.g. explosive, toxic,
hot) substances must be discharged such
that no danger to people or the environment
occurs. Legal regulations must be observed.
Safety instructions for instal-
lation, inspection and main-
tenance works
As a basic principle, works may only be car-
ried out to the equipment when it is shut
down. Pumps or plant that convey harmful
substances must be decontaminated.
All safety and protection components must
be re-fitted and/or made operational imme-
diately after the works have been completed.
Their effectiveness must be checked before
restarting, taking into account the current
regulations and stipulations.
Unauthorised modifications,
manufacture of spare parts
The equipment may only be modified or al-
tered in agreement with the manufacturer.
The use of original spare parts and acces-
sories approved by the manufacturer is im-
portant for safety reasons. The use of other
parts can result in liability for consequential
damage being rescinded.
Unauthorised operating
methods
The operational safety of the supplied equip-
ment is only guaranteed if the equipment is
used for its intended purpose. The limiting
values given in the "Technical Data" sec-
tion may not be exceeded under any circum-
stances.
Instructions regarding acci-
dent prevention
Before commencing servicing or maintenance
works, cordon off the working area and check
that the lifting gear is in perfect condition.
Never work alone. Always wear a hard hat,
safety glasses and safety shoes and, if nec-
essary, a suitable safety belt.
Before carrying out welding works or using
electrical devices, check to ensure there is
no danger of explosion.
People working in wastewater systems must
be vaccinated against the pathogens that
may be found there. For the sake of your
health, be sure to pay meticulous attention to
cleanliness wherever you are working.
Make sure that there are no toxic gases in the
working area.
Observe the health and safety at work regula-
tions and make sure that a first-aid kit is to
hand.
In some cases, the pump and the pumping
medium may be hot and could cause burns.
For installations in areas subject to explosion
hazards, special regulations apply!
This appliance can be used by children aged
8 years or over and by persons with limited
physical, sensory or intellectual capabilities,
or with limited experience and knowledge,
provided that they are supervised or have
been instructed in the safe use of the appli-
ance and are aware of the dangers involved.
Children must not be allowed to play with the
appliance. Cleaning and user maintenance
must not be carried out by children unless
they are supervised.

Publicité

loading