Working Ranges, Angles, Distances, Tolerances And Measuring Accuracy - Linear Application - Balluff BML SL1-ALZ-ZZ Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
4
Installation and connection (continued)
4.3.3
Working ranges, angles, distances, tolerances
and measuring accuracy – Linear application
The different mounting tolerances must be met depending
on the required measuring accuracy (see different working
ranges and maximum function range in Tab. 4-2).
Fig. 4-6:
Distances and tolerances with linear applications
Z
(air gap sensor/magnetic tape)
Z
(air gap between sensor/magnetic
tape with cover strip)
Y (lateral offset)
Pitch
Yaw
Roll
Max. non-linearity of entire system
(sensor head + magnetic tape)
Non-linearity of sensor head
Hysteresis
Repeat accuracy
Tab. 4-2:
Working ranges, angles, distances and tolerances and
measuring accuracy
www.balluff.com
27.3
Y
+Yaw
–Yaw
Z
Working range 1
≤ 0.4 mm
≤ 0.25 mm
±0.5 mm
±15 µm
±5 µm
≤  1 µm
≤ 1 µm
During assembly, make sure that the sensor head is
correctly positioned over the magnetic tape. The distances
and tolerances must be complied with to ensure the
correct function and linearity class of the system specific to
the application.
–Roll
+Roll
5
5
–Pitch
+Pitch
Working range 2
≤ 1.0 mm
≤ 0.85 mm
±1.0 mm
±0.5°
±1°
±0.5°
±40 µm
±30 µm
≤ 2 µm
≤ 2 µm
Active measuring surface
Free area of
magnetizable material
Travel direction:
forward,
A (sin) before B (cos)
Z
Function range
≤ 1.3 mm
≤ 1.15 mm
±1.5 mm
±100 µm
±40 µm
≤ 2 µm
≤ 2 µm
english
11

Publicité

Table des Matières
loading

Table des Matières