Balluff BML SL1-ALZ-ZZ Série Notice D'utilisation page 87

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
7
IO-Link Smart Sensor profile Ed. 2 (BML SL1-ALZ1-UE/MZZ-_U1L-...) (continued)
7.6
Diagnostic data
The BML reports diagnostic data (Events) to the controlling
system (see Tab. 7-20) or the controlling system can read
the status using the diagnostics parameters.
7.6.1
Diagnostics parameters
Index
Subindex
Parameters
0x0024 (36)
0
Device Status
0x0025 (37)
0
Detailed Device
Status
0x0028 (40)
0
Process Data Input
Tab. 7-20: Diagnostics parameters
7.6.2
Event list
Event code Characteristic
0x8D00
Notification
0x8D01
Notification
0x8D02
Warning
0x8D03
Warning
0x8D04
Error
0x8D06
Warning
0x4210
Warning
0x4220
Warning
0x4000
Error
0x5000
Error
0x8D07
Error
Tab. 7-21: Event list
www.balluff.com
Size
Access
1 bytes
Read Only
9 bytes
Read Only
6 bytes
Read Only
Meaning
LIMITED ACCURACY PLUS – The head is located in the detection range but outside the
set measuring range.
LIMITED ACCURACY MINUS – The head is located in the detection range but outside the
set measuring range.
OUT OF RANGE PLUS – The head is outside the detection range. No valid data is output.
The transmitted process data value is 0×7FFFFFF8 and 2'147'483'640.
OUT OF RANGE MINUS – The head is outside the detection range. No valid data is
output. The transmitted process data value is 0x80000008 and –2'147'483'640.
NO MEASUREMENT DATA – No head detected. No valid data is output. The transferred
process data value is 0×7FFFFFFC or 2147483644.
MEASUREMENT DATA UNSAFE – The function reserve is too low. The application must
be checked.
DEVICE TEMPERATURE OVERRUN (see Section 7.5.6) – The set upper temperature
warning threshold has been exceeded.
DEVICE TEMPERATURE UNDERRUN (see Section 7.5.6) – The set upper temperature
warning threshold has been underrun.
TEMPERATURE OVER RUN ERROR – The temperature has exceeded the specified
maximum temperature. The heat source must be eliminated.
HARDWARE FAULT – There is a problem with the device hardware. Interrupt power to
restart the BML. If the problem occurs again, replace the BML.
OPEN CIRCUIT AT CURRENT OUTPUT – The analog current output is open, check
installation.
Values
0 = Normal status
2 = Warning
4 = Error
Up to 3 active Events:
1st byte Event type (0 = no Event,
0xE4 = Warning, 0xF4 = Error)
2nd and 3rd byte Event code (see Sec. 7.6.2)
The last valid process data (see Sec. 7.2)