5
ELECTRICAL CONNECTIONS
A- ARS24C with 24Vdc control panel with encoder (ABC2MARC9)
B- AR220C with 230Vac control panel without encoder (AEP20TOP)
C
Capacitor
FC1 End of travel 1
FC2 End of travel 2
M
Motor
1 Complete the connections as shown in the figure:
1 Green cable: encoder signal
2 White cable: power supply (-) encoder
3 Brown cable: power supply (+) encoder
4 Blue cable: motor (24Vdc)
5 Red cable: motor (24Vdc)
2 Use PUL1, PUL2, PUL3, PUL4 to check the correct
operation of the actuator.
Check the instructions for the control panel in
order to install the other electrical components.
3 Adjust the ends of travel so they act as a travel
stopper (see "Adjust the ends of travel" on page 32).
1 Complete the connections as shown in the figure:
1 Yellow/green cable: earth
2 Brown cable: turn 1
3 Grey cable: common
4 Black cable: turn 2
2 Use PUL1, PUL2 to check the correct operation of
the actuator.
Check the instructions for the control panel in
order to install the other electrical components.
3 Adjust the travel using the ends of travel of the
actuator (see "Adjust the ends of travel" on
page 32).
INSTALLATION
ARC electro-mechanical actuator
33