Fitting
The condensation tray is fitted to the rear edge of the
EcoAir base plate. Fit the enclosed tape to the edge of
the plate to prevent direct contact between the plates
Picture 3
and the risk of corrosion development.
The stay is fitted to the front of the base beam as shown
in the picture. A 12.5 mm diameter hole must be drilled
in the beam to fit the stay. It should be drilled ap-
proximately 12 mm from the bottom of the beam and
approximately 383 mm from the left edge of the beam
as shown in picture 3. There are differences between
EcoAir models. Therefore test fit the condensation tray
14
Picture 4
Groove in con-
densation tray
Outlet. The outlet
external diameter is 50
mm and fits PEM pipe
connections. A hose with
a suitable diameter can
alternatively be used.
before drilling the hole.
Fit the rubber nut into the 12.5 mm hole. Then fit the
stay, the washer and the bolt in that order as shown in
picture 4. Ensure that the stay is as centred as possible in
the notch in condensation tray.