6
Additional installation suggestions which, from experience, reduce the effect of
electromagnetic interference:
• Make line connections as short as possible.
• Use shielded lines (e.g. LIYCY 4 x 0.5 mm²)
• The cable shielding must be fitted by qualified personnel, subject to the ambient conditions
and with the aim of suppressing interference.
• Keep the instrument well away from the electrical supply lines of power equipment, as well
E
as from any electrical or electronic equipment causing interference.

4 Pin assignment

Connector Binder series
714 M18
EN175301 – 803 (DIN 43650)
M12x1
Edition: 2013-06-21
2
3
1
4
1
2
3
HYDAC ELECTRONIC GMBH
HDA
Pin
4844 - A
1
n.c.
2
Signal +
3
Signal -
4
n.c.
HDA
Pin
4845 - A
1
Signal +
2
Signal -
3
n.c.
4
Housing
HDA
Pin
4846 - A
1
Signal +
2
n.c.
3
Signal -
4
n.c.
HDA
HDA
4844– B
4844 - E
+U
+U
B
B
Signal
Signal
0V
0V
n.c.
n.c.
HDA
HDA
4845– B
4845 - E
+U
+U
B
B
0V
0V
Signal
Signal
Housing
Housing
HDA
HDA
4846– B
4846 - E
+U
+U
B
B
n.c
n.c
0V
0V
Signal
Signal
Part No.: 669868