– Do not cut rebates or grooves without fitting a
suitable guard, e.g. a tunnel-type guard, over the
saw table.
– Circular saws must not be used for slotting jobs
(cutting grooves which end in the workpiece).
– When transporting the electric tool, only use
the transport devices. Never use the protective
devices for handling or transport.
– Make sure that the upper part of the saw blade
is covered during transport, e.g. by the protective
device.
– Be sure to only use spacers and spindle rings
specified by the manufacturer as suitable for the
intended purpose.
– The floor around the machine must be level,
clean and free of loose particles, such as chips
and cutting residues.
– Always stand to the side of the saw blade when
working with the saw.
– Do not remove any cutting residues or other
parts of workpieces from the cutting zone while
the machine is running and the saw unit is not
at rest.
– Make sure that the machine is always secured
on a workbench or a table if at all possible.
– Support long workpieces (e.g. with a roller table)
to prevent them sagging at the end of a cut.
– m Attention! Never remove loose splinters, chips
or jammed pieces of wood while the saw blade is
running.
• Switch off the machine to troubleshoot or remo-
ve jammed pieces of wood. - Disconnect the
main power plug -
• Refitting, including adjusting and measuring
works, and cleaning must be carried out only
when the motor is switched off. - Disconnect
the main power plug -
• Before switching on again, ensure that keys
and adjustment tools have been removed.
Warning! This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.
SAFETY INSTRUCTIONS FOR THE HANDLING OF
SAW BLADES
Only use insertion tools if you have mastered their
1
use.
Observe the maximum speed. The maximum
2
speed specified on the insertion tool may not be
exceeded. If specified, observe the speed range.
3
Observe the motor / saw blade direction of rota-
tion.
Do not use any insertion tools with cracks. Sort out
4
cracked insertion tools. Repairs are not permitted.
5
Clean grease, oil and water off of the clamping
surfaces.
6
Do not use any loose reducing rings or bushes for
the reducing of holes on saw blades.
Make sure that fixed reducer rings for securing the
7
insertion tool have the same diameter and have at
least 1/3 of the cutting diameter.
8
Make sure that fixed reducer rings are parallel to
each other.
9
Handle insertion tool with caution. They are ideally
stored in the originally package or special contain-
ers. Wear protective gloves in order to improve
grip and to further reduce the risk of injury.
24 І 148
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
10 Prior to the use of insertion tools, make sure that
all protective devices are properly fastened.
11 Prior to use, make sure that the insertion tool
meets the technical requirements of this electric
tool and is properly fastened.
12 Only use the supplied saw blade for sawing opera-
tions in wood, materials similar to wood, plastics
and non-ferrous metals (except for magnesium and
alloys containing magnesium).
Residual risks
The machine has been built according to the state of
the art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use of
improper electrical connection cables.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the „safety instruc-
tions" and the „Proper use" are observed along with
the whole of the operating instructions.
• Do not load the machine unnecessarily: excessive
pressure when sawing will quickly damage the saw
blade, which results in reduced output of the machine
in the processing and in cut precision.
• When cutting plastic material, please always use
clamps: the parts which should be cut must always
be fixed between the clamps.
• Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet.
• Use the tool that is recommended in this manual. In
doing so, your saw provides optimal performance.
• Hands may never enter the processing zone when the
machine is in operation. Release the handle button
and switch off the machine prior to any operations.
• Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
6. Technical data
AC motor
performance
operating mode
Idle speed
Hard-metal blade
Number of teeth
Thickness riving knife
table size
Cutting height max. 90°
Cutting height max. 45°
height adjustment
saw blade swivel
suction port
weight
* operating mode S6 20%: Continuous operation with in-
termittent loading (playing time 10 min).
Engine protection of to hot warming up:
It´s allowed to run the engine with nominal power maximum
20% of playing time. After this the machine must run 80% of
playing time steadily without load.
220-240 V~ 50Hz
2000 Watt
S6 20%*
4800 min
-1
ø 255 x ø 30 x 2,8 mm
60
2,5 mm
640 x 640 (920) mm
80 mm
50 mm
0 - 80 mm
0 - 45°
ø 40 mm
31,5 kg