Diagnostics; Fuses; Error Messages; Warning - Beninca YAK 20 OM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38

13) DIAGNOSTICS

In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and
safety) can be displayed. One segment of the display is linked to each input. In the event of failure it
switches on according to the following scheme.

14) FUSES

F1
Protection fuse of transformer
F2
Output protection fuse of accessories and signals
F3
Output protection fuse for motor and blinker

15) ERROR MESSAGES

Some messages that are displayed in the event of malfunctions are shown hereunder:
Motor
Err1
Error, PHOT O circuit check
Err4
Error, PHOT C circuit check
Err5
Error, encoder
ENC
Obstacle detection
Amp

16) WARNING

The RC product insurance policy, which covers any injuries or damages to objects caused by manufacturing defects, requires the use of Benincà's
original accessories.
Technical assistance is required.
Check connections, alignment of PHOT O photocell or obstacle present.
Check connections, alignment of PHOT C photocell or obstacle present.
Error to connection or faulty encoder.
An obstacle present is indicated (anti-crash device).
SWC
SWO
P.P.
PED
OPEN
CLOSE
PHOT 0
STOP
PHOT C
DAS
EN
29