10 . tEChNICAL dAtA

Sensor
Operating principle
Measurement range
Guaranteed tolerance
(of the measured value)
Accuracy
Minimum bending radius
Diameter of the smallest
measuring area
Critical base layer thickness
Operating temperature
Operational relative humidity
Dimensions
Weight
G
F
Magnetic induction
0 ~ 1250 µm
0 ~ 49,21 mils
0 ~ 850 µm (+/- 3% + 1 µm)
850 µm ~ 1250 µm (+/- 5 %)
0 ~ 33,46 mils (+/- 3 % + 0,039 mils)
33.46 mils ~ 49,21 mils (+/- 5 %)
0 ~ 50 µm (0.1 µm)
50 µm ~ 850 µm (1 µm)
850 µm ~ 1250 µm (0,01 mm)
0 ~ 1,968 mils (0,001 mils)
1,968 mils ~ 33,46 mils (0,01 mils)
33,46 mils ~ 49,21 mils (0,1 mils)
1,5 mm
7 mm
0,5 µm
0 °C ~ 40 °C (32 °F ~ 104 °F)
20 % ~ 90 %
(H×D×W): 110 × 50 × 23 mm
100 g
Operating manual – layer thickness measuring instrument BB 20
N
Eddy current
0 ~ 1250 µm
0 ~ 49,21 mils
0 ~ 850 µm (+/- 3% + 1,5 µm)
850 µm ~ 1250 µm (+/- 5 %)
0 ~ 33,46 mils (+/- 3 % + 0,059 mils)
33,46 mils ~ 49,21 mils (+/- 5 %)
0 ~ 50 µm (0,1 µm)
50 µm ~ 850 µm (1 µm)
850 µm ~ 1250 µm (0,01 mm)
0 ~ 1,968 mils (0,001 mils)
1,968 mils ~ 33,46 mils (0,01 mils)
33,46 mils ~ 49,21 mils (0,1 mils)
3 mm
5 mm
0,3 µm
B - 11