. colouring. often. has. the. appearance. of. cracks,. it. .
. does. not. in. any. way. impair. the. way. the. device. .
. works. and. should. not. be. treated. as. a. fault . . The. .
. discolouring. will. disappear. when. hot. air. from. a. .
. hair.dryer,.for.example,.is.applied .
10 . . Y ou.can.also.use.heat.to.restore.any.deformations. .
. to. the. housing. to. their. original. condition. and. to. .
. remove. any. dents. which. have. occurred. as. a. re-.
. sult. of. some. form. of. impact. (e .g . . a. knock. or. a. .
. blow) . . Please.contact.our.Customer.Support.Team. .
. for.more.advice .

06. TROUBLESHOOTING

Only little or no air is being suctioned off:
•. Check.to.see.if.the.suction.hoses.that.are.connec-.
. ted.to.the.water.separator.are.free.or.blocked . .
•. Check.to.see.if.the.suction.hoses.that.are.connec-.
. ted.to.the.core.drill.holes.are.free.or.blocked .
•. Check.to.see.if.the.hoses.of.the.DA.3.are.free.or. .
. blocked . . In.order.to.do.so.dismantle.the.air.intake. .
. and.discharge.hoses.and.look.through.the.adapter. .
. pieces . . If.you.can.look.through.them,.then.they.are. .
. free .
•. Check.to.see.if.the.air.intake.grille.in.the.turbine,. .
. air.ducts.(coarse.particle.protection).or.the.water. .
. separator.inlets.are.soiled.or.blocked . .
•. Check.to.see.if.the.water.separator's.demister.is. .
. soiled.or.not .
•. Check.to.see.if.the.water.separator's.micro.filter.is. .
. soiled.or.not .
The device is not controlling the suction current
•. Check.that.the.device.is.switched.on .
•. Check.that.the.control.lamp.is.on .
•. Check.the.ducts.to.see.if.they.are.blocked . . In.order. .
. to. do. so. dismantle. the. air. intake. and. discharge. .
. hoses.and.look.through.the.adapter.pieces . . If.you. .
. can.look.through.them,.then.they.are.free .
G
07. INTERIOR VIEW OF THE MQ DA3
The.figure.below.shows.the.schematic.configuration.
of.the.installation.with:
1 . . Control.valve
2 . . Inlet.and.outlet
3 . . Mains.adapter
4 . . Control.unit
5 . . Relay
6 . . Mains.connection
7 . . Start.key
8 . . Housing

08. TECHNICAL DATA

Article.number . . . . . . . . . . . . . . . . . . 6 .100 .000 .030
Connection.voltage. . . . . . . . . . . . . . . . . . . . 1~230.V
Dimensions. . . . . . . . . .435.mm.x.435.mm.x.255.mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 .2.kg
Air.transport.hoses. . . . 2.x.3.adapters.with.38.mm.Ø