guest-room use a minimum temperature. Confirm your choice by pressing the F
button; the display will stop blinking. If you set no temperature, the display will
stop blinking after 7 seconds and will be automatically set to 22°.
HO=home
If you do nothing further, the heater will maintain the set temperature during the day
and at night. Imagine, you have set the heater to 21°C, but would like it to be set to
18°C during working days:
1. Press on a working day at 08.00 on the '5' for five seconds: the display will show
an 'h' and then a blinking '05'. Use the + and – to change the figure to the desired
number of hours for which you wish to reduce the temperature: from 08.00 to
16.00 is 8 hours so set '08' and confirm with the F button.
2. Now the display will show a blinking 'd' and then a blinking figure. Set which
(working) day it is: 1=Monday, 2=Tuesday and so on until 5 (Friday). Confirm with
the F button.
3. Now the display will show a blinking '°C' followed by a blinking '17'. Use the + and
– buttons to set the temperature between 08.00 and 16.00 (in the example, this is
18°C). Confirm with the F button.
4. The green control light '5 day setting' will now blink slowly to signal that the heater
is allowing the room to cool down.
The heater will now let the room cool down to 18°C on Monday to Friday between
08.00 and 16.00 and then heat it up again to 21°C.
If you wish to reduce the night-time temperature (so for 7 nights), you proceed in a
similar manner. Imagine you wish to set the temperature from 23.00 to 06.00 to 16°C:
5. Press on a random evening at 11.00 on the '7' for five seconds. The display will
show an 'h' and then a blinking '05'. Use the + and – to change the figure to the
desired number of hours for which you wish to reduce the temperature: from
23.00 to 6.00 is 7 hours so set '07' and confirm with the F button.
6. Now the display will show a blinking '°C' followed by a blinking '17'. Use the + and
– buttons to set the temperature between 23.00 and 6.00 (in the example, this is
16°C). Confirm with the F button.
7. The green control light '7 day setting' will now blink slowly to signal that the heater
is allowing the room to cool down.
The heater will now let the room cool down to 16°C every day between 23.00 and
6.00 and then heat it up again to 21°C.
OF=office:
For office use, you set the standard temperature for nights and weekends. To set the
daily temperature for five working days higher, follow steps 1 to 4 under HO=home
but set the daytime temperature higher than the standard temperature.
CA=cabin (guest room or similar):
For guest room use, you can set the number of days that the heater must heat the
room.
On the first day, press the '7' button in for 5 seconds. The 'd' will blink and then
'01' will appear in the display. Use the + and – buttons to set the number of days
for which the room must be heated. Confirm with the F button.
Now the display will show a blinking '°C' followed by a blinking '10'. Use the + and
– buttons to set the daytime temperature. Confirm with the F button.
The green control lights will continue to blink while the heater is functioning.
Your guests can alter the set temperature by pressing on + or -.