Instrument calibration
Before using the instrument the following parameters must be set:
choice of unit of measurement (metres or feet);
Set the type of sensor (Standard or Electronic);
Gipsy diameter setting (default value 33 cm) and division factor;
Use
Press the
(ON) key to activate controls and to switch on the display lighting. The display lighting
switches off 30 seconds after the last command given (adjustable default time – see "BkLight Time").
Press key
(UP) to control the anchor ascending.
Press key
(DOWN) to cast anchor.
When any key is released (UP or DOWN) the corresponding action is stopped.
Measurement reset
To reset the measurement count simultaneously press the
three seconds.
Measurement reset may also be performed in the Measurement menu by selecting "Yes" in the Reset
Measure row.
Automatic casting of the anchor
This function must be enabled in the Alarms and Functions menu (disabled by default).
Select the row "Auto Down" and set the value at which the anchor must stop. Then press the
and
(DOWN) keys for at least three seconds. Once anchor casting has commenced, release the keys.
For safety reasons it is however possible to interrupt automatic descent by pressing any
instrument key.
EV-030
Alarms & Functi
U p A l a r m
3 . 0
A u t o D o w n
O f f
L o a d D e f a u l t
N o
E x i t
27
English
(ON) and the
(UP) keys for at least
(ON)
Rev. 15 – 2022