Use the
(DOWN) or
Language
The user may select the display language:
Italian, English, French, German, Spanish
Exit
To return to the settings menu.
Sensor calibration menu
Sensor
This function selects the sensor type:
2-wire standard sensor (STD)
3-wire electronic sensor (HAL)
Barbotin Circumference
In this row the user must enter the
circumference of the gipsy (in centimetres or
inches).
Settable values: centimetres or inches.
Default value, 33 cm.
Division Factor
If the standard 2-wire electronic sensor
(STD) is used, this value must be left at 1.
if an electronic sensor is used it must be
equal to the number of sensor pulses for
each turn of the barbotin. See paragraph
"Instrument calibration".
Exit
To return to the settings menu.
EV-030
(UP) key to move around the parameters.
Select with
Select value with
Confirm with
Confirm with
Sensor Calibrat.
Sensor
B a r b . C i r c .
D i v i s o r F a c t .
Exit
Select with
Select value with
Confirm with
Select with
Select value with
Confirm with
Select with
Select value with
Confirm with
Confirm with
S t a n d a r d
3 3 . 0
1
24
English
Rev. 15 – 2022