Closing flange
Stainless steel or
aluminium airtight
closing flange
2.5.10

INSTALLING A COMBUSTION AIR INTAKE

Every solution described allows for the following alternatives:
Outside air drawn through a duct (inner Ø: 50mm; max.
length 1.5 m) connected to the air intake located on the
rear of the stove.
Air drawn directly from the room of installation, provided
that there is an air intake near the stove of at least 100 cm²
on the wall communicating with the exterior
In both cases, it is important to periodically verify that air pas-
EN
EN
sage is not obstructed.
IMPORTANT: This appliance cannot be used in
the event of shared flue .
2.6

ELECTRICAL CONNECTION

Ensure that the electrical system and sockets can withstand
the maximum power consumption of the product, shown on
the identification plate.
• Ensure that the system is earthed and
equipped with a residual current device, in
compliance with the standards in force
The stove must be connected to a standard electric sock-
et, 230v – 50Hz voltage, without using adapters, multiple
sockets or extension cables.
Ensure that the mains connection cable is not in contact
with the hot parts of the stove and that it is not crushed
by it.
The stove system is protected by a fuse inserted in the
master switch at the rear of the product.
Always remember to unplug the product before perform-
ing any maintenance and/or checks and whenever a long
idle period is foreseen.
14
External air intake
with non-lockable
grille
Inspection
fig. 10 external flue
fig. 11 electric connection of the stove
Once the power cable at the back of the stove is plugged in,
move the switch, also located at the back, to (I) therefore:
The switch at the back of the stove is for powering the sys-
tem.
There is a fuse box at the back of the stove near the power
socket. Open the lid of the fuse box with a screwdriver and
have an authorised technician change any fuses if neces-
sary (3.15 A delayed).
Socket
3

FIRST IGNITION

Before commissioning the product, it is manda-
tory to have specialised personnel perform the
"FIRST IGNITION" and calibration. To this end,
we recommend contacting the authorised
Zantia
shall not be held liable for malfunctions caused by improper
company
installation, failed or improper first ignition or misuse. Before
switching the product on, always check that the brazier
is pushed to the back of the rear wall of the combustion
chamber. When the tank is loaded the first time, the auger
must fill up for a certain amount of time during which the pel-
lets are not dispensed into the brazier.
3.1

PELLET LOADING PROCEDURE

Fuel is loaded by opening the door at the top of the stove.
Pour the pellets slowly until they deposit at the bottom of
the tank.
Never remove the protective grid inside the
tank. Do not allow the pellet bag to come into
contact with hot surfaces while loading.
Do not insert any other type of fuel in the tank
except pellets compliant with the specifi ations shown
previously.
Store spare fuel a safety distance away from the stove.
Do not pour pellets directly into the brazier, but only into the tank.
translated from the original text
fig. 12 electric power supply
technical
assistance
Mod. CINEA CANALIZÁVEL
First ignition
Stove switch
Fuse box
centre.