making it necessary to use the minimum heights provided
in fig. 5.
•
The chimney must be windproof and be higher than the
ridge (see fig.5).
•
The chimney must be positioned away from buildings or
other obstacles that are higher than the chimney itself
(see fig.5).
fig. 5 allowed and forbidden chimney installation methods
Horizontal
width of the
Roof slope [G]
backflow area
EN
from the ridge
axis A[m]
15
30
45
60
2.4.4
INSTALLING A COMBUSTION AIR INTAKE
Every solution described allows for the following alternatives:
•
Outside air drawn through a duct (inner Ø: 50mm; max
length 1.5 m) connected to the air intake located on the
rear of the boiler.
•
Air drawn directly from the room of installation, provided
that there is an air intake of at least 100 cm² on the wall
communicating with the exterior (ref. UNI10683).
In both cases, it is important to periodically verify that air pas-
sage is not obstructed.
IMPORTANT: This appliance cannot be used in the
event of shared flues.
36
flat roof
sloped roof
Minimum
Height of the
height of roof
backflow area
outlet Hmin =
Z+0.50m
1.85
1.00
1.50
1.30
1.30
2.00
1.20
2.60
tab.1
2.5
POSITIONING
2.5.1
GENERAL NOTES
IT is prohibited to install the stove in bedrooms,
bathrooms, in rooms with showers and in rooms
with another heating appliance without appro-
priate ventilation (fireplace, boiler, etc.), outdoors
exposed to weather agents or in moist areas.
The stove must be installed in a place that allows for safe and
easy use and simple maintenance. That place must be provid-
ed with an electric system earthed as required by standards in
force.
ATTENTION: make sure that the electric connec-
tion plug is accessible even after installation of
the boiler.
In the event of heat sensitive or flammable flooring, this must
be protected (e.g., by means of steel sheets, marble slabs or
tiles).
Two ventilation holes (200x200mm size at least) must be pre-
sent in the base of the module and in the ehxaust fan.
In case the holes are not present, the functioning of the mod-
ule is compromised and the guarantee expires.
Note: The hole in the base of the hearth must coincide with
the hole in the base of the module.
Z [m]
0.50
0.80
1.50
2.10
translated from the original text
Installation
Mod. CRONOS rev 01