Troubleshooting
The switch-off procedure is immediately activat-
ed.
6.4
EXTINCTION DURING OPERATION
ALARM
If the fire goes out during operation and the flue gas temper-
ature drops below the minimum operating threshold, this
alarm is triggered immediately.
fig. 36 control panel - extinction during operation alarm
The switch-off procedure is immediately activat-
ed.
6.5
AUGER SAFETY PRESSURE SWITCH
ALARM
If the pressure switch (negative pressure meter) detects pres-
sure lower than the triggering threshold, it triggers by cutting
power to the auger and simultaneously displaying the mes-
sage "Alarm Dep Fail", stopping the system.
fig. 37 control panel - auger safety pressure switch alarm
6.6

GENERAL THERMOSTAT ALARM

If the general safety thermostat detects a temperature higher
than the triggering threshold, it is triggered by cutting power
to the auger and simultaneously displaying the message
"ALARM SIC FAIL", stopping the system.
fig. 38 control panel - general thermostat alarm
6.7
FAULTY FLUE GAS EXTRACTION FAN
ALARM
If the flue gas extraction fan is faulty, the product stops and
displays the message "ALARM FAN FAIL".
The switch-off procedure is immediately activat-
ed.
fig. 39 control panel - flue gas extraction fan alarm
rev 00
Mod. CINEA CANALIZÁVEL
7

PROBLEMS

7.1

THE PELLETS DO NOT IGNITE

In the event of failed ignition, the alarm message "NO ACC"
[IGNITION FAILED] is displayed.
Press the key (4) to restore standard conditions.
fig. 40 control panel - failed pellet ignition
7.2

POWER FAILURE (BLACK-OUT)

In the event of a power failure, upon restoration, the stove en-
ters in "FINAL CLEANING" mode and waits for the flue gas tem-
perature to drop to a value preset by the manufacturer.
After a power failure, the stove will try to go back to the
prior condition. Only if power remains cut for longer than
the time set by the manufacturer, the product will switch
off au omatically when power is restored.
translated from the original text
fig. 41 control panel -power failure