Troubleshooting
SYMPTOM
Pump does not run when water
flows in from sink
Pump runs, but does not empty
sink
Pump cycles on and off when
no water is in the sink
Pump cycles on and off when the
sink is at maximum water
flow or is full
Hydromatic warrants to the original consumer of the products listed below, that they will be free from defects in
material and workmanship for one year from date of installation, or 18 months from date of manufacture.
Our warranty will not apply to any product that has been subject to negligence, misapplication, improper instal-
lation or maintenance. In the event a three phase submersible motor is operated with single phase power
through a phase converter, or if three-leg ambient compensated, extra-quick trip overload relays of recom-
mended size are not used, our warranty is void.
Buyer's only remedy and Hydromatic's only duty is to repair or replace defective products (at Hydromatic's
choice). Buyer agrees to pay all labor and shipping charges associated with this warranty and to request war-
ranty service through the installing dealer as soon as a problem is discovered. If warranty service is requested
more than 30 days after the Warranty Period has ended, it will not be honored.
HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
WARRANTY PERIOD PROVIDED HEREIN.
Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of
limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply.
This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may
vary from state to state.
Supersedes all previous publications.
Phone: 419-207-3372 • Fax: 419-281-4087 • Web Site: http://www.hydromatic.com
POSSIBLE CAUSE(S)
Pump unplugged.
Outlet unpowered.
Pump impeller jammed.
Sink stopper in drain.
Drain clogged.
Clogged discharge line.
Shut-off valve closed.
System discharge line too
high or too long.
Check valve installed
backwards
Check valve not installed.
Check valve jammed.
Shut-off valve not adjusted.
Shut-off valve not installed.
HYDROMATIC LIMITED WARRANTY
HYDROMATIC
740 East 9th Street, Ashland, OH 44805
CORRECTIVE ACTION
Plug in pump.
Check fuse / breaker.
Unplug pump; follow procedure under "Maintenance"
to clear pump.
Remove stopper.
Clear drain screen.
Unplug pump, open and clear discharge line.
Open shut-off valve slightly.
Unplug pump and reduce height or length of discharge line
(11' Max. Height).
Make sure flow arrow on check valve points away
from pump.
Unplug pump and install check valve (see Figures 2
and 3, Pages 3 and 4).
Unplug pump; open discharge line and clean check valve.
See "Adjusting the Flow", Page 3.
Unplug pump and install shut-off valve (see Figures 2
and 3, Pages 3 and 4).