GARANT GridLine workbench, self-propelled with electric drive
5.6.1. Removing the drawers
I
(Fig.
)
1. Actuate the lock under the handle and pull the drawer out to its full extent.
2. Push the side levers back and swing them up.
» The drawer is now released.
3. Remove the drawer.
5.6.2. Inserting the drawers
en
J
(Fig.
)
1. Pull the drawer runners out to their full extent and secure them.
» Check that the drawer runners run correctly in their guides on the workbench.
2. Reinsert the drawer and push it in until you sense resistance.
3. Slightly raise the drawer and push it past the resistance.
4. Continue to push the drawer in until it is fully supported by the rails.
5. Swing the side levers down and push them forwards.
» The drawer can now be pushed fully home.
6. Repeat the procedure for the other drawers.
6. Displays and signals for the operating modes
6.1. CONTROL HANDLE
System
Battery
6.1.1. System LED
LED display
Continuous red LED display
Flashing red LED display
Continuous green LED display
Flashing green LED display
96
The battery LED on the control handle indic-
ates only an approximate value.
The state of charge should be read directly at
the battery.
Press the power knob on the battery. The
display switches off automatically.
Acoustic signal
-
Interval
-
-
Instruction manual
Meaning
System initialised
System error reported
Faults table [} 99]
System ready for operation
System operational, drive unit
extended