– With the rotary push button (8), select the "Set time" sym-
bol in the menu bar (4).
The hour display flashes.
– Set the hours with rotary push button (8).
– The minutes display flashes when the rotary push button (8)
is tapped again.
– Set the minutes with rotary push button (8).
– Tap the rotary push button (8) to confirm the value.
Service menu
1. Calibrating the room temperature sensor of the
heater (OFFSET)
The room temperature sensor of the heater can be individ-
ually adjusted to the sensor's installation situation. The set-
ting can be made in increments of 0.5 °C within the range of
0 °C to -5 °C.
Example:
hot
Set room temperature 23 °C;
OFFSET = -1 °C;
– Setpoint value for heater = 22 °C
Default setting: 0 °C (Celsius).
2. AC SET
1,2
When automatic climate control is running, the room tem-
perature may be perceived differently in heating and cool-
ing modes. "AC SET" is used to set an offset between cooling
and heating. The setting can be made in increments of 0.5 °C
from 0 °C to +5 °C.
Example:
hot
Set room temperature 23 °C;
AC SET = 2 °C
– Setpoint value for air conditioning
system = 25 °C
Default setting: +1 °C (Celsius).
1
Only available if the air conditioning system and heater are
connected.
2
Only available if ACC is set to "ON".
3. ACC
1
The automatic climate control function AUTO is activated or
blocked with "ACC".
ON
– The automatic climate control function AUTO
is activated. Automatic climate control function
AUTO can be selected in the Room temperature
menu.
– "AC SET" appears in the Service menu.
OFF
– The automatic climate control function AUTO is
blocked.
Default setting: OFF
Truma automatic climate control will function properly
only if it is installed correctly. Your Truma Partner will be
pleased to advise you whether your vehicle is suitable.
hot