Problem
There is too much frost and
ice.
Water flows on the rear plate
of the refrigerator.
Water flows inside the refriger-
ator.
Water flows on the floor.
The temperature in the appli-
ance is too low/too high.
22
Possible cause
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
The water drainage plug is
not correctly positioned.
Appliance is fully loaded and
it is set to the lowest temper-
ature
Temperature set in the appli-
ance is too low and the am-
bient temperature is too
high.
Temperature is set incorrect-
ly.
During the automatic de-
frosting process, frost melts
on the rear plate.
Food products prevent the
water to flow into the water
collector.
The water outlet is clogged.
The melting water outlet is
not connected to the evapo-
rative tray above the com-
pressor.
The temperature regulator is
not set correctly.
The door is not closed cor-
rectly.
The food products' tempera-
ture is too high.
Many food products are stor-
ed at the same time.
The thickness of the frost is
greater than 4-5 mm.
The door has been opened
often.
There is no cold air circula-
tion in the appliance.
Solution
Refer to "Closing the door".
Position the water drainage plug
in the correct way.
Set a higher temperature. Refer
to "Operation".
Set a higher temperature. Refer
to "Operation"
Refer to "Operation" .
This is correct.
Make sure that food products do
not touch the rear plate.
Clean the water outlet.
Attach the melting water outlet to
the evaporative tray.
Set a higher/lower temperature.
Refer to "Closing the door".
Let the food products tempera-
ture decrease to room tempera-
ture before storage.
Add less food products at the
same time.
Defrost the appliance.
Open the door only if necessary.
Make sure that there is cold air
circulation in the appliance.