• This appliance contains 130g of R290
refrigerant gas.
• R290 is a refrigerant gas that complies with
European environmental directives. Do not
pierce any part of the refrigerant circuit.
• If the appliance is installed, used, or stored
in a non-ventilated area, the room must be
designed to prevent the accumulation of
refrigerant leaks that could result in a fire or
explosion hazard due to refrigerant ignition.
caused by electric heaters, stoves, or other
sources of ignition.
• The device must be stored in such a way as
to prevent mechanical failure.
• Those who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited body that
guarantees proficiency in the handling of
refrigerants according to a specific assessment
recognized by industry associations.
• Repairs must be made according to the
manufacturer's recommendations.
• Maintenance and repairs that require the
assistance of other qualified personnel must be
performed under the supervision of a person
specified in the use of flammable refrigerants.