Mna - Mna-X; Precautions - DAB NOVA UP Série Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
a) MA
Figure 7
Level On
(cm)
NOVA UP MA
29
300-180
NOVA UP MA
33
600
Difference
Level Off
ON-OFF
(cm)
(cm)
12
17
16
17
b) MNA - MNA-X
Figure 8

9. PRECAUTIONS

• RISK OF FROST: when the pump remains inactive at a tempe-
rature lower than 0°C, it is necessary to ensure that there is no
water residue which could freeze, causing cracks in the plastic
parts.
• If the pump has been used with substances that tend to form
a deposit, rinse it after use with a powerful jet of water in order
to avoid the formation of deposits or encrustations which would
reduce the characteristics of the pump.
• Ensure that the float switch does not touch the walls of the trap
during operation.
• Ensure that the OFF level is not too close to the suction grid,
minimum height below the filter 60/70mm.
ENGLISH
GB
21

Publicité

Table des Matières
loading

Table des Matières