Anti-Static Bar Information Parameters (Expert Mode); Adjusting The Hv Output Frequency Parameter (Expert Mode); Switching Bar Remotely On/Off Through The Remote On/Off Input On The Manager Or Via Fieldbus (Expert Mode) - Simco-Ion ThunderION IQ 2.0 Notice D'utilisation

Masquer les pouces Voir aussi pour ThunderION IQ 2.0:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If you do not want the bar to activate automatically after a power interruption or disconnection,
the autorun parameter in expert mode (6.2) has to be set to no.
[
(n)x

6.2.4 Anti-static bar information parameters (expert mode)

If desired, various information parameters can be entered as required to make the different
devices more recognisable.
If desired, adjust the parameters: Device name, Machine position, Mounting distance. These
are information parameters neither the bar or the manager will use for calculations.
- Select the information page with the parameters to be changed by:
- [
,
,
(n)x

6.2.5 Adjusting the HV output frequency parameter (expert mode)

For most applications, the default setting of 5 Hz for the output frequency will be sufficient for
achieving optimal neutralisation. For special applications it might be beneficial to adjust the
output frequency.
Here, for a shorter mounting distance in relation to the object to be neutralised or higher speeds
of the object, the frequency can be increased for a better result. For greater distances, reducing
the frequency can be beneficial.
By default, the frequency is set to 5 Hz, but can be set to a different value in specific cases.
- [
(n)x
slide slider or with
with
]
6.2.6 Switching bar remotely on/off through the remote on/off input on the manager or
via fieldbus (expert mode)
If desired, the manager can be switched on/off using the remote on/off input of the Manager or
by means of an instruction of the optional Fieldbus (see user manual of the Manager).
Using this, one machine control can switch several selected devices on/off at the same time
without any actions by the operator, including this bar.
For selecting this, the Remote on/off source parameter has to be changed from Continuous to
Remote or Fieldbus.
- [
(n)x
ThunderION2ThunderIONIQ2_UM_9752160050_NL_D_GB_F_V2_3
"No"]
Autorun
"parameter
"HV output frequency"
to the desired value and confirm
"Remote on/off source"
", enter name or value", confirm with
select Remote or Fieldbus ]
]
GB
77

Publicité

Table des Matières
loading

Table des Matières