6.2.1 Selecting EXPERT mode for setting parameters or maintenance
In order to set parameters and carry out maintenance, you need expert user privileges. A
password may be required. For a detailed description, please refer to chapter 6.4 of the manual
Manager IQ Easy.
Once logged in at this user level, you will remain on this level until selecting a new user level.
- Go to the main screen
- Enter the password and confirm with
the manager, if no password is required.
- Click
and then click on device to check and/or change the parameters by clicking
behind the parameter or desired action.
- By clicking
6.2.2 Operating modes (expert)
The anti-static bar has 4 operating modes:
1 Fixed
The anti-static bar has a fixed ionisation. Ionisation works like a ThunderION 2.0. A fixed
number of positive and negative ions are produced. Depending on the application, the static
charge will be neutralised and residual charge will remain.
2 Manual
For test applications or very specific applications the ratio between positive and negative ions
(balance) can be set manually. In position 0, the same amount of positive (+) and negative (-)
ions will be produced (fixed), where -100 = maximum negative and +100 = maximum
positive.
3 CLFB (Closed Loop FeedBack)
For this mode a Sensor bar IQ Easy bar has to be connected to the platform. After the film or
object to be neutralised has passed the ThunderION IQ, the sensor will measure the residual
charge. This value is communicated to the ionisation bar which will regulate the ratio of
positive and negative ions automatically, so that the residual charge will be as close to
neutral (0) as possible.
4 Auto tune (not yet available)
ThunderION2ThunderIONIQ2_UM_9752160050_NL_D_GB_F_V2_3
, select settings
you will return to the main screen.
and choose expert.
or return directly to the system settings page of
74