5 Installation
- Electrical installation and repairs must be carried out by a skilled electrical engineer
according to the applicable national and local regulations.
- The equipment must be properly earthed. Earthing is required to ensure safe and
proper operation and to prevent electrical shocks upon contact.
- Disconnect the power supply before carrying out work on the unit.
- The anti-static bar must only be powered by a Limited Power Source (LPS) or
NEC Class 2 power supply. An LPS certified power supply has a limited output power,
which means that it always generates a safe output voltage.
- Only connect the specified voltages to the circuits.
The 0 V of the power output must be earthed correctly (see section 5.2.3.).
The anti-static bar can be powered by a 24 V DC power supply already available on the
machine (if it meets the above requirements), but also by a power unit from Simco-Ion
Netherlands.
The power units recommended by Simco-Ion Netherlands:
Part number
Description
4524001000
Desktop, 100–240 V AC to 24 V DC for 1 ThunderION (IP40).
4510001400
Control module for max. 4 ThunderION's (IP 54)
7519020425
DIN rail power supply 100–240 V AC to 24 V DC for 1 ThunderION (IP20).
7519020430
DIN rail power supply 100–240 V AC to 24 V DC for 1 ThunderION (IP20).
7519020435
DIN rail power supply, 100–240 V AC to 24 V DC for a maximum of 5
ThunderION's (IP20).
1030000000
Manager IQ Easy DC 24V
1030000010
Manager IQ Easy AC 100-240V
1030000100
Extension IQ Easy DC 24V
1030000110
Extension IQ Easy AC 100-240V
5.1 Prior check
- Check that the equipment is free from damage.
- Check that the details on the packing slip correspond to the details of the product received.
If you have any problems and/or doubts, please contact Simco-Ion Netherlands or the agent in
your region.
5.2 Fitting the anti-static bar
Note:
- Conductive machine parts in the vicinity of the anti-static bar have a negative
influence on its operation.
- For optimum results, the anti-static bar must be fitted as per Figure 5.
- For minimum distances, see Figure 6.
- If the distances for optimum results can't be met, keep a distance of at least 50 mm
from the side of bar to electrically conductive machine parts.
- Use the supplied mounting brackets