6.2.2.2 Operating mode CLFB (Closed Loop FeedBack) with sensor IQ Easy (not yet
available)
After the CLFB mode is selected, a sensor has to be coupled for using the measurement values
for regulation: Go to section 6.2.2.3. for coupling a sensor.
6.2.2.3 Coupling sensor bar values
The sensor bar has to be connected to the
ThunderION IQ. With the next page
to the parameter Paired sensor.
- Click behind Paired sensor
- Select the Sensor IQ Easy which will provide the anti-static bar with measurement values.
- With several sensor segments , a sensor segment can be
switched off.
This may be necessary in case you are using a smaller
conveyor and hence a segment of the sensor will be outside
of the area of the conveyor. The anti-static bar will then
calculate using the average measurement values of the
active (enabled) segments.
To disable a segment, click
-
Select the segments to be disabled.
Confirm the selection with
The anti-static bar will now show the average (avg) of the enabled segments in the parameters
and the Graphics Tab (and use the average to regulate ionisation – not yet implemented –).
6.2.3 Anti-static bar standby & active
By default, the bar will become active once the manager has gathered all the information,
because the parameter autorun is set to yes.
On each tab, you can set the device to standby
The status is indicated in the left upper corner by means of the background colour of the
icon:
Green = standby, blue = running, orange = warning, red = alarm.
ThunderION2ThunderIONIQ2_UM_9752160050_NL_D_GB_F_V2_3
icon , go
behind Enabled segments.
and set autorun
or active
mode.