Safety Precautions - ALLURIS FMI-100 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Thank you for having chosen one of our high-quality digital force gauges. Please read this operation manual
thoroughly before using this instrument for the first time. Thus, you will be able to use your newly purchased
instrument accurately, to achieve accurate and reproducible results, and to avoid damages.

1.0 Safety precautions

The internal sensor (load measuring cell) can be damaged due to overload! Mind your gauge
model`s maximum measuring range! The maximum measuring range is stated on your
instrument`s front side and on the type label on the back. Do not apply side or radial forces to the
rigid measuring axle. Do not use any tools to screw measuring attachments onto the measuring
axle.
Always transport and store the instrument in its carrying case when not in use. Thus, you will
minimize the risk of damages caused by unmeant detrimental mechanical effects, which, as the
case may be, can destroy the internal sensor.
Take note of the correct environmental conditions. Do not operate or store the instrument in harsh
or dirty environments. The instrument is equipped with a temperature compensation for 0°...40°C.
Use the instrument in this temperature range only.
Please only use the threaded holes on the rear side of the instruments for test stand mounting.
The M16x2 threads are exclusively for the detachable handles of FMI-300/400 series instruments
and are laid out for a maximum load of 250 kg.
2.0 Before taking into operation
2.1. Unpacking and inspecting the delivery`s volume
The force gauges are delivered in carrying cases. Especially the instruments for small forces should be
exclusively transported therein as strokes and strong agitation may damage the measuring cell. Please inspect
the content before taking the instrument into operation. The following table provides an overview of the
delivery`s volume as well as the single components` order number in case you want to purchase them at a later
point in time.
Carrying case (FMI-910 for FMI-100 to
FMI 220; FMI-911 for FMI-300 and FMI-
400)
Base model (see type plate with serial
number and specification of measuring
range on the back)
Net-charger (FMI-945)
Operation manual (20025)
Hooks (FMI-962 M4 / FMI-962 M6 / FMI-
962 M10)
Cone point (FMI-965 M4 / FMI-965 M6 /
FMI-965 M10)
Chisel (FMI-963 M4 / FMI-963 M6 / FMI-
963 M10)
Slotted pan head (FMI-961 M4 / FMI-961
M6 / FMI-961 M10)
Groove head (FMI-964 M4 / FMI-964 M6
/ FMI-964 M10)
FMI-100
FMI-200
FMI-210
FMI-
FMI-
100BU
200BU
200BU
(-/ /-)
( / /-)
( / /-)
(-/ /-)
( / /-)
( / /-)
(-/ /-)
( / /-)
( / /-)
(-/ /-)
( / /-)
( / /-)
(-/ /-)
( / /-)
( / /-)
19
FMI-220
FMI-230
FMI-
FMI-
FMI-
220BU
230BU
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
( / /-)
FMI-300
FMI-400
FMI-
FMI-
300BU
400BU
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )
(-/-/ )

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fmi-300Fmi-200Fmi-210Fmi-400Fmi-220Fmi-230

Table des Matières