D PTING THE
TYPES OF G S
If a different gas from that one indicated on the label is used, you need to adapt the cooktop
to this new situation.
If the injectors are not supplied they can be obtained from the "Service
Centre".
Select the injectors to be replaced according to the table on next page.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body
of each injector.
OPER TIONS TO BE PERFORMED WHEN SUBSTITUTING
THE INJECTORS
Remove the pan-supports and the burner covers;
Using a wrench substitute the injectors "J" (Figs. 6.3 - 6.4) with those ones suitable for
the type of gas for which it is to be used.
The burners are conceived in such a way so as not to require the adjustment of the
primary air.
Fig. 6.3
PPLI NCE TO FUNCTION WITH DIFFERENT
J
Fig. 6.4
J
25