Textron Ransomes Frontline 728 Série Manuel De Maintenance page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MAINTENANCE
FUEL FILTER
1. To change the fuel filter only, first remove the
see-through water separator bowl. See water
fuel separator procedure on the previous page.
2. Remove the large black retaining ring G.
3. Pull the filter element straight down. Do not
twist as the filter element is not threaded.
4. Dispose the old filter element according to local
laws.
5. Align key in flter element with the slot in the
header and push the new filter element up into
the filter head.
6. Place retainer ring G. Hand tighten retainer
ring until it clicks and the arros line up in the
center of the header.
NOTE: Always bleed the fuel system of air after
removing the water from the separator.
COOLANT
The quantity of fluid in the coolant system is
indicated by the fluid level in overflow bottle O.
Keep the overflow bottle approximately 1/4-1/2
full.
When filling, use a 50/50 mixture of antifreeze
and water.
HYDRAULIC NOTES
Lower implements attached to lift arms to relieve hydraulic pressure from system before servicing.
When servicing hydraulic pipe fittings, do not use teflon tape. Use a liquid sealant that will dissolve into
system.
Make sure all hydraulic connections are tight before applying pressure to system.
When checking for leaks, do not use your hands to attempt to feel a spray. Instead, pass an object like
cardboard over hydraulic system components to visualize a spray. Escaping hydraulic fluid can be under
sufficient pressure to penetrate skin and cause serious injury. If injured by escaping hydraulic fluid, see a
doctor at once. Serious infection or reaction can develop if proper medical treatment is not administered
immediately.