Pumpable Liquids; Technical Data - DAB ESYBOX DIVER Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
The ideal working situation is with the pump completely submerged; however, the motor cooling system allows its use up to the minimum
suction height (110 mm).
These pumps cannot be used in swimming pools, ponds or basins where people are present, or for pumping hydrocarbons
(petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the accident-prevention regulations in force. They should
be cleaned before putting them away (See chapter "Maintenance and Cleaning").
1.2

Pumpable Liquids

Only use the pump in clean water.
The pump must not be used to pump salt water, sewage, inflammable, corrosive or explosive liquids (e.g. petroleum, petrol,
thinners), greases, oils.
The temperature of the liquid to be pumped must not exceed 50°C (122°F).
If the pump is used for the domestic water supply, respect the local regulations of the authorities responsible for the management
of water resources.
Maximum size of solid particles dispersed in the liquid: Diameter 1 mm (0.04 in)
1.3

Technical Data

ESYBOX DIVER pumps are equipped with a filter, which can be opened (see figure 1, A) or closed (called X) (see figure 1, B), depending on
the application.
The open filter prevents the passage of suspended particles with a diameter greater than 2.5 mm.
Inside there is a splitter that prevents suction from the bottom, up to a level of 80mm. It is possible to cut or remove it to be able to suck water up
to a minimum of 35mm from the bottom. (see figure 2).
Products with filter X are characterized by the X next to the pump name.
The filter X is characterized by a base, which is not watertight, with a 1'' female connection. The filter X is designed to be used with the KIT X :
suction kit with float (see figure 3).
Pump models are identified as below (Table 1):
55/120
All technical data are marked on the technical label on the pump.
The various items are explained below:
ENGLISH
P1 [W]
1250
Q MAX [l/min – m3/h – gpm]
120 – 7.2 – 31.7
Table 1
17
H MAX [m – psi]
55 – 78

Publicité

Table des Matières
loading

Table des Matières