10. CHANGING THE CONTROL PANEL
Before doing any work on the appliance, always make
sure it is unplugged from the wall socket!
In.the.event.of.a.defect.in.the.control.panel.it.may.be.
necessary.to.replace.it.completely . .
Please proceed as follows.
1 . . Raise.the.upper.part.of.the.housing .
2 . . Loosen.the.four.screws.on.the.corners.of.the.control. .
. . panel.and.take.the.panel.out .
3 . . Unplug.the.plugs.(
. . and.if.necessary.also.unplug.the.plugs.3-5 .
4 . . Use.a.small.screwdriver.to.loosen.the.screws.of.the. .
. . central. power. connection. XI. and. pull. the. cable. out.
. . of.the.clamp .
5 . . Loosen.any.other.connections . . (X3,.X2)
6 . . You.can.now.pull.out.the.circuit.board.completely .
11. CONNECTIONS ON THE CIRCUIT BOARD
Connection
Description
X1
Power.supply.230V.AC.(L,.N,.and.6.x.PE)
X2
Zero-potential.malfunction.reporting.relay
X3
External.water.sensor.(zero.current)
1
Fan.connection.230V.AC
Water.pump.230V.AC
2
3
Rinsing.pump.230V.AC
Magnetic.valve.230V.AC
4
UV.lamp.230V.AC
5
X9
Water.sensors,.10.litre.to.50.litre
.
B - 6
,
,.X9).vfrom.the.circuit.board.
1
2
Operating manual – Infrared camera
7 . . Now. attach. the. individual. connection. to. the. new. .
. . circuit. board. in. the. reverse. order . . Note. the. num-.
. . bers. on. the. plugs. and. the. circuit. board. when. ma-.
. . king.the.plug-in.connections .
8 . . Insert.the.control.panel.back.into.the.shaft.and.fasten. .
. . it.with.the.four.screws .
9 . . Now. replace. the. upper. part. of. the. housing. back. .
. . onto.the.B.500 .
The.appliance.is.protected.by.a.conventional.fuse.with.
the.rating.of.2.AT .
Power supply
230V.50Hz
42V
-
230V.50Hz
230V.50Hz
230V.50Hz
230V.50Hz
230V.50Hz
-
Power
consumption
200.VA
1A
-
65.VA
25.VA
25.VA
10.VA
6.VA
-