Changing The Control Panel - Trotec B 500 Mode D'emploi

Masquer les pouces Voir aussi pour B 500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ers are equipped with a BIO filter (Order No . 1603) as
standard (high evaporation capacity) . Foam filters (Or-
der No . 1601) are also still available . In addition, we
also offer a special activated charcoal cleaning filter
in a 2-pack (Order No . 1605) .
m In order to ensure perfect operation, only
use Original Replacement Filters and Origi-
nal Replacement Parts. We undertake no re-
sponsibility or warranty for any water dam-
age or reductions in performance.
1 . Remove the two clips by pressing them together .
2 . Release filter from 4 retaining lugs .
B - 4
3 . Fit new filter in reverse order, secure clips and
make sure that the filter rests within the bottom
U-shaped rail over the entire length of the water
distribution .
m Particular care must be taken to ensure the
two side clips are fitted correctly otherwise
the filter may make contact with the upper
section of the housing, thus causing leaks.

10. Changing the control panel

m Before doing any work on the appliance,
always make sure it is unplugged from the
wall socket!
In the event of a defect in the control panel it may be
necessary to replace it completely .
Please proceed as follows.
1 . Raise the upper part of the housing .
2 . Loosen the four screws on the corners of the con-
trol panel and take the panel out .
3 . Unplug the plugs (
board and if necessary also unplug the plugs 3-5 .
4 . Use a small screwdriver to loosen the screws of the
central power connection XI and pull the cable out
of the clamp .
5 . Loosen any other connections . (X3, X2)
6 . You can now pull out the circuit board completely .
7 . Now attach the individual connection to the new
circuit board in the reverse order . Note the num-
bers on the plugs and the circuit board when mak-
ing the plug-in connections .
8 . Insert the control panel back into the shaft and fas-
ten it with the four screws .
9 . Now replace the upper part of the housing back
onto the B 500 .
The appliance is protected by a conventional fuse
with the rating of 2 AT .
Operating Manual – Electronic Humidifier
,
, X9) vfrom the circuit
1
2
EN

Publicité

Table des Matières
loading

Table des Matières