humidification . . Working. against.
lime.scale,.it.can.also.significantly.
increase. the. lifetime.of.the.evapo-
ration.filter .

19. CLEANING

The.device.should.be.cleaned.of.calcium.(lime).depo-
sits.and.soiling.every.3-4.months . . For.this.purpose,.
the.upper.section.of.the.housing.is.detached,.the.filter.
removed. and. the. centre. plate. cleaned . . A. commer-
cially. available. cleaning. agent. can. be. used. for. this.
purpose . . All.traces.of.the.cleaning.agent.must.be.re-
moved.(rinse.thoroughly.with.clean.water) .
Do not use benzene or other solvents that attack plastic..
The.humidifier.sh-.
ould.be.cleaned.th-.
oroughly. once. a.
year.(preferably.by.
our. maintenance.
service) . . Use.com-
mercially.available.
limescale. remover.
(decalcifying.agent).to.remove.lime.residue . . Then.rin-
se.thoroughly.with.clean.water . . The.water.distributor.
is. open. at. the. top,. easily. accessible. and. should. be.
cleaned.of.any.residue . . If.blocked,.the.drain.holes.in.
the. water. distributor. can. be. cleaned. with. a. knitting.
needle. or. similar . . While. cleaning,. check. to. ensure.
there. are. no. sludge. deposits. in. the. pump. hoses . . If.
necessary,. they. should. be. cleaned. with. a. narrow.
bottle. brush. or. they. should. be. replaced . . Should. the.
equipment. remain. out. of. service. for. longer. periods,.
the.residual.water.is.to.be.emptied.out,.the.filter.is.to.
be.removed.and.cleaning.is.to.be.carried.out .
B - 12
20. ACCESOIRES (OPTIONAL EXTRAS)
Automatic water supply
The.connection.to.the.local.water.main.must.be.made.by.
a.qualified.specialist,.i . e . . a.licensed.installation.technician . .
(Please.note.the.water.supply.utility's.regulations . . It.may.
be.advisable.to.fit.a.back-flow.stop.valve . ) .
We.recommend.our.1 . 5 -metre.long.safety.pressure.hose.
for.the.connection.between.the.water.pipe.and.the.appli-
ance.(Product.no.1754) . T he.automatic.system.for.topping.
up.the.water.incorporates.a.magnetic.valve . . In.the.factory.
the.appliance.is.set.at.automatic.water.supply.at.a.maxi-
mum.fill.level.of.30.litres,.i . e . . when.the.fill.level.reaches.
30.litres.the.water.supply.is.shut.off . . If.the.water.supply.is.
active,.this.is.shown.by.a.running.light.(10-50.litre.diodes.
flash.on.after.the.other) . . The.water.supply.is.controlled.by.
the.electronic.rods.in.the.water.level.display . . To.ensure.
faultless.functioning.of.the.automatic.water.supply.it.is.
therefore.necessary.for.the.electrode.rods.to.be.cleaned.
regularly.with.a.sponge.and.freed.of.any.deposits.of.chalk.
or.dirt . . In.order.to.avoid.overfilling,.when.the.fill.level.of.
50.litres.is.reached.a.malfunction.message.is.issued,.i . e . .
the. appliance. is. automatically. switched. off,. an. audible.
warning.signal.is.given,.and.Fault.Code.04.appears.in.the.
display . . If.the.water.supply.is.defective.and.the.water.le-
vel.does.not.change.although.the.magnetic.valve.is.open,.
the.process.is.terminated. and.Fault.Code.01.appears.in.
the.display . . Please refer to the next page (Rinsing sys-
tem) for a sketch and the dimensions..We.recommend.for.
safety's.sake.that.our.safety.collection.tub.(Product.no . .
1752).should.be.used,.connected.to.our.safety.water.sen-
sor.(Product.no . . 1757),.or.that.an.addition.external.water.
valve.should.be.used.(Product.no . . 1753) .
Water.supply.
The maximum water pressure must not exceed
10 bar!