Filling; Water Level Indicator; Filter Change Indicator - Trotec B 500 Mode D'emploi

Masquer les pouces Voir aussi pour B 500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

. . . SET button
3
.
With.the.Set.button.you.can.select.from.the.sub-.
.
menus.Taste.(21,.22,.23.).in.programming.mode . . .
.
If.no.other.settings.are.made,.after.10.seconds. .
.
the.display.automatically.jumps.back.to.the.stan-.
.
dard. display. figure,. i .e . . indoor. atmospheric. hu-.
.
midity . . Changes.that.have.been.made.to.the.re-.
.
quired.humidity.setting.or.in.programming.mode. .
.
are.saved .
.
4
PROG button
.
Pressing. this. button. opens. the. programming. .
.
mode.of.the.B.500.so.that.you.can.select.from. .
.
the.main.menus.(10,.20,.and.30) . . See.page.9.for. .
.
a.description.of.the.menus .
.
.
Flush button
5
.
Pressing.this.button.activates.the.rinsing.system . .
.
(optional.extra)
.
6
ON/OFF-Taste
.
The.appliance.can.be.switched.on.or.off.by.pres-.
.
sing.this.button .
Supplied with two 24G Size AAA 1.5V batteries.
Please do not use any other type!

07. FILLING

(not applicable for humidifiers with automatic water
supply)
The.device.is.filled.with.water.via.the.upper.filler.flap.
using.a.watering.can.(only.up.to.the.max . . level.mark,.
50.litres) . . The.water.level.is.indicated.by.light.emitting.
diodes. (max . . 5. stages) . . Both. normal. tap. water. and.
softened.water.can.be.used.to.operate.the.humidifier . .
Do not use distilled water! Take care to fill cor-
rectly, since spilt water could enter the equipment
and cause a short circuit. The maximum tempe-
rature of the water must not exceed 35 °C.
B - 4

08. WATER LEVEL INDICATOR

The.water.level.is.sensed.by.copper.electrodes.and.is.in-
dicated.by.LEDs.on.the.control.panel . . The.device.switches.
off.automatically.if.the.red.„Top.up.water".LED.comes.
on . . A.small.quantity.of.water.always.remains.in.the.tank.
(approx . . 15. litres) . . It. is. advisable. to. regularly. (approx . .
every.3-4.weeks).drain.off.the.residual.water.depending.
on.the.degree.of.soiling.and.calcium.(lime).content . . The.
opportunity.should.be.taken.to.clean.the.water.tank.with.
a.sponge.or.a.wet.vacuum.cleaner . . The.electrode.rods.
require.occasional.cleaning.to.ensure.they.do.not.indica-
te.incorrect.values.or.cause.the.humidifier.to.shut.down.
owing.to.calcification.of.the.voltage.electrodes . . Distilled.
water.must.not.be.used.because.it.leads.to.malfunctions.
in.the.water.level.indicator .
. . . ...

09. FILTER CHANGE INDICATOR

The. B. 500. atmospheric. humidifier. has. a. filter. change.
indicator . . The. frequency. with. which. the. filter. needs. to.
be.changed.depends.on.the.length.of.time.for.which.the.
pump.runs,.the.hardness.of.the.water,.and.the.fan . . Un-
der.the.best.circumtstances.it.will.have.to.be.changed.
after.98.days,.in.the.worst.after.56.days,.but.this.is.only.a.
recommendation;.the.situation.can.be.affected.one.way.
or.the.other.by.such.external.factors.as.air.pollution.or.
the.hardness.of.the.water . . In.any.case.it.is.advisable.to.
make.regular.visual.checks.of.the.filter.Please.see.the.
section.on.„Changing.the.filter".for.detailed.instructions . .
When.you.have.changed.the.filter.you.have.to.reset.the.
indicator.manually.to.its.initial.position . . Please.proceed.
as.described.in.the.section.on.„Menu.programming".to.
Menu.33,.where.you.can.reset.the.filter.change.indicator.
at.any.time.to.its.initial.position.of.98.days .