Menu Programming - Trotec B 500 Mode D'emploi

Masquer les pouces Voir aussi pour B 500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fault code
Fault
01
Water.tank.is.empty
02
UV.lamp.defective
03
Water.leaking
(only.possible.with.external.water.
sensor)
04
Water.tank.overfilled
(only.possible.with.automatic.
water.supply)
05
No.radio.signal.from.hygrostat . .
The.receiver.on.the.control
panel.has.not.received.a.signal.
for.a.quite.some.time .
09
Several.faults.have.occurred.
simultaneously

16. MENU PROGRAMMING

The. B. 500. Professional. offers. you. the. possibility. of.
changing.the.factory.settings.and.making.various.set-
tings.to.meet.your.requirements . .
Please proceed as follows:
1 . . Press.the.„PROG".button.on.the.remote.control.unit. .
. . „Prog" .
2 . . The.number.„10".will.appear.on.the.control.panel. .
. . display .
3 . . Select.one.of.the.main.menus.(10,.20,.or.30,.see. .
. . table.below) .
4 . . Once. your. have. reached. the. main. menu. you. are. .
. . looking.for,.press.the.„SET".button.to.reach.the.re-.
. . quired.sub-menu,.e .g . . 11,.12,.or.13 .
G
What to do?
• Check.water.level.and.top.up.if.necessary .
•.Check.water.level.diodes.for.dirt.and.clean.if.necessary .
•.Has.distilled.water.been.used?.If.so,.top.up.with.plain.
...tap.water .
•.Check.the.diodes.connection .
•.Is.the.automatic.water.supply.defective?.
...(optional.extra)
• Replace.UV.lamp . . (see.„Changing.the.UV.tube")
•.Check.whether.the.filter.has.been.inserted.correctly .
•.Check.whether.the.appliance.is.standing.upright .
•.Check.whether.the.automatic.water.supply.is.working.
...correctly.(if.fitted) .
•.Check.tank.for.leaks . .
•.Check.the.function.of.the.magnetic.valve .
•.Check.the.water.level.diodes.for.dirt .
•.Is.the.radio.transmitter.too.far.away.from.the.appliance?
•.Check.the.function.and.coding.of.the.radio.transmitter.
...(see.„Starting.up"./.„Coding.the.radio.sensor.system") .
•.Replace.the.batteries.if.necessary .
•.Check.the.appliance.as.described.for.Faults.01.to.04 .
5 . . Once.your.have.reached.the.sub-menu.you.are.loo-.
. . king.for,.after.a.few.seconds.the.display.will.flash. .
. . with.a.number.such.as.00,.01,.or.98 . . By.pressing. .
. . the. blue. „Humidity". button. (%). you. can. increase. .
. . the.figure.with.'+'.or.decrease.it.with.'-' .
6 . . When.you.have.made.the.necessary.change,.sim-.
. . ply.wait.for.about.10.seconds . . After.that.the.display. .
. . will. jump. back. to. the. standard. position. (showing. .
. . relative.humidity).and.the.changes.will.be.saved .
Operating manual – Infrared camera
B - 9

Publicité

Table des Matières
loading