23. MAINTENANCE CHECK LISTS

Only authorised and qualified staff are permitted to carry out the following work!
Cleaning.and.operation.instruction.
(Always.disconnect.mains.supply.plug.before.performing.any.work.on.the.device!!!)
Time
Cleaning and operating instructions
interval*
(Always disconnect mains supply plug before performing any work on the device!!!)
Every day •.Visual.check.of.water.level.via.LED.display.(10-50).litres . . Device.switches.off.automatically
... . a t.residual.water.level.of.approx . . 15.litres .
... . � .Does.not.apply.in.case.of.automatic.water.supply .
• Visual.check.of.indicated.humidity.value.via.digital.display . .
3-5
•.Lift.upper.part.of.device.upwards .
weeks
• Visual.check.of.filter . . In.case.of.strong.pollution.replace.filter . . (Use.original.filters.only,.other
... . w ise.operation.of.the.device.may.be.impaired) . . When.inserting.the.new.filter,.always.take.care.
that.it.will.be.inserted.flush.with.water.distribution.system.(see.operation.manual.„Replacing.
filters") . .
... . � .The.two.lateral.snap.bows.of.the.filter.must.be.inserted.properly,.since.otherwise.the.filter.
can.come.into.contact.with.the.upper.part.of.the.casing,.which.may.cause.water.escapes .
•. Please.check.at.the.same.time.whether.the.outlet.holes.in.the.water.distribution.system.
... . a re.free.from.residues . . Remove.any.residues.such.as.lime.or.dust.for.instance,.by.means.of.
a.needle,.a.screwdriver.or.even.use.a.vacuum.cleaner.for.this .
•.Lift.middle.part.of.device.off.in.upward.direction .
•.Remove.remaining.water.from.the.water.container.and.clean.the.tub.(bottom.part) .
.... � .This.is.necessary.in.particular.when.using.fresh.water.in.order.to.avoid.higher.concentra-
tions.of.residues .
• Visual.check.of.the.copper.electrode.bars.(see.operation.manual) . . Remove.lime.and.other
.... r esidues.by.means.of.a.household.sponge,.or.if.necessary.use.a.rag.for.this .
12-16
•.As.described.in.the.above.section.the.filter.must.be.replaced.after.12.to.16.weeks.in.any
weeks
.... c ase,.since.otherwise.the.operation.of.the.device.may.be.impaired . . When.replacing.the.filter.
check.the.water.distribution.for.passage .
•.After.this.time.has.elapsed.and.in.case.of.heavy.calcification.and.dirt.deposits.the.water.tub.
.... ( bottom.part).should.be.cleaned.by.means.of.an.anti-lime.agent.from.an.anti-lime.agent.that.
is.customary.in.the.trade . . After.cleaning.with.such.an.agentalways.rinse.the.water.tube.well.
in.order.to.avoid.residues.remaining.in.the.device .
12
•.General.cleaning.of.the.device.by.means.of.anti-lime.agent
months
.... - .clean.pump.tubes.using.a.bottle.brush.or.replace.them
.... - .clean.the.body.of.the.fan.by.using.the.extension.nozzle.of.the.vacuum.cleaner
.... - .clean.the.body.of.the.pump
.... - .clean.the.copper.electrodes
G
Operating manual – Infrared camera
B - 17

Publicité

Table des Matières
loading

Table des Matières