Filter change
Depending.on.the.operating.time.of.the.humidifier,.the.
special.filter.is.used.up.during.the.course.of.time.as.a.re-
sult.of.mineral.deposits.in.the.water.and.dust.deposits.in.
the.air.(every.8-16.weeks.depending.on.the.water.hard-
ness,.dust.accumulation.and.operating.time) . . The.filter.
should.not.be.washed.as.this.reduces.the.evaporation.
capacity.of.the.device . . All.humidifiers.are.equipped.with.
a.BIO.filter.(Order.No . . 1603).as.standard.(high.evapora-
tion.capacity) . . Foam.filters.(Order.No . . 1601).are.also.still.
available . . In.addition,.we.also.offer.a.special.activated.
charcoal. cleaning. filter. in. a. 2-pack. (Order. No . . 1605) . . .
In order to ensure perfect operation, only use
Original Replacement Filters and Original Re-
placement Parts. We undertake no responsi-
bility or warranty for any water damage or
reductions in performance.
1 . . Remove.the.two.clips.by.pressing.them.together .
G
*
Operating manual – Infrared camera
2 . . Release.filter.from.4.retaining.lugs .
3 . . Fit.new.filter.in.reverse.order,.secure.clips.and.make. .
. . sure.that.the.filter.rests.within.the.bottom.U-shaped. .
. . rail.over.the.entire.length.of.the.water.distribution .
Particular care must be taken to ensure the two
side clips are fitted correctly otherwise the filter
may make contact with the upper section of the
housing, thus causing leaks.
*
*
*