Note: If no more settings have been made for 10 se-
conds the display will jump back to the standard po-
sition (showing relative humidity). The programming
process can be terminated at any time by pressing
the ON / OFF button. Please note, however, that this
will result in the loss of all the changes that have been
made.
Main
Sub-
menu
menu
10
11
12
13
14
15
20
21
22
23
24
25
26
B - 10
Description
Hooter setting
Hooter.active.when.tank.
empty
Hooter.active.when.UV.
lamp.is.defective.
Hooter.active.with.external
water.sensor.alarm
Hooter.active.when.tank.
content.>=50.liters
Hooter.active.when.no.
radio.signal
Relay setting
Relay.active.when.tank.
empty
Relay.active.when.UV.lamp.
is.defective
Relay.active.with.external
water.sensor.alarm
Relay.active.when.tank.
content.>=.50.Litre
Relay.active.when.no.radio.
signal
Relay.switch.status
(Low=.Relay.active.open
High=.Relay.active.closed)
Operating manual – Infrared camera
Setting
Comment
00.=.OFF
.
01.=.ON
00.=.OFF
Only.at.version.with
01.=.ON
UV-C-technology
00.=.OFF
With.external.sensor
01.=.ON
00.=.OFF
(Only.in.combination.with.automatic
01.=.ON
water.supply)
00.=.OFF
01.=.ON
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
00.=.OFF
Only.necessary.with.connection.to.a
01.=.ON
central.air-conditioning.system
Factory
setting
01
01
01
01
01
00
00
00
00
00
00
G