Technical Data; Drainalarm Gsm Software Version; Type Overview; Scope Of Delivery - Wilo DrainAlarm/-GSM Notice De Montage Et De Mise En Service

Masquer les pouces Voir aussi pour DrainAlarm/-GSM:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

TRANSPORTATION AND STORAGE

switchgear via the acknowledgement button, via
an external acknowledgement button or by text
message command.
The power supply is also monitored. If the power
supply is interrupted, a visual and audible alarm
signal will also be sent.

3.5. Technical data

Mains connection:
Ambient/operating temper-
ature:
Storage temperature:
Max. relative humidity:
Protection class:
Switching capacity of po-
tential-free alarm outputs:
Alarm output switching
capacity:
Housing material:
Dimensions (W x H x D):

3.6. DrainAlarm GSM software version

See the rating plate for the latest version of
the DrainAlarm GSM and the delivered software
version. The rating plate is attached to side of the
housing.

3.7. Type overview

DrainAlarm
Alarm switchgear with battery
Alarm switchgear with battery and GSM
DrainAlarm GSM
module

3.8. Scope of delivery

3.8.1. DrainAlarm
• Alarm switchgear with built-in battery and power
cable with shockproof plug
• 2x threaded cable connections M16 x 1.5
• Installation and operating instructions
3.8.2. DrainAlarm GSM
• Alarm switchgear with pre-assembled GSM mod-
ule (without SIM card), built-in battery and power
cable with shockproof plug
• GSM antenna
• USB cable
• CD-ROM with configuration software and ex-
tended installation and operating instructions
• Screwdriver
• 2x threaded cable connections M16 x 1.5
• 1x threaded cable connection M20 x 1.5
• Installation and operating instructions

3.9. Accessories

• Float switch for wastewater and sewage free of
faeces
Installation and operating instructions Wilo DrainAlarm/-GSM
1~230 V, 50/60 Hz
-20...50 °C
-20...+60 °C
50%
DrainAlarm: IP 68
DrainAlarm GSM: IP 54
(if GSM antenna is connect-
ed: IP 44)
250 V AC/DC, max. 4 A
12 VDC, max. 1 A
Polycarbonate
200 x 120 x 95 mm
• Float switch for abrasive sewage containing
faeces
Accessories have to be ordered separately.
4. Transportation and storage

4.1. Delivery

On delivery, check immediately that the ship-
ment is complete and undamaged. If any parts
are damaged or missing, the transport company
or the manufacturer must be notified on the day
of delivery. Claims made after this date cannot be
recognised. Damage to parts must be noted on
the freight documentation.

4.2. Transport

Only the packaging used by the manufacturer or
supplier may be used for transport. This normally
precludes the possibility of damage occurring
during transportation and storage. The packaging
should be stored in a safe place for reuse if the
product is frequently used at different locations.
NOTE
The blade connector at the plus contact (+) of
the battery must be pulled for alarm switch-
gear DrainAlarm and DrainAlarm-GSM. The plus
contact (+) on the battery must insulated with
the bushing provided!

4.3. Storage

On delivery, alarm switchgears may be placed into
temporary storage for up to 2 years until use.
The following should be taken into consideration
for storage:
• Store the properly packaged alarm switchgear on
a firm subsurface.
• The alarm switchgears may be stored from -20 °C
to +60 °C at a max. relative humidity of 50%.
The store room must be dry. We recommend a
frost-protected room for storage with a tem-
perature between 10 °C and 25 °C and a relative
humidity of 40% to 50%.
Avoid condensation!
• Seal the threaded cable connections securely to
prevent ingress of moisture.
• Connected power supply cables should be pro-
tected against kinking, damage, and moisture.
BEWARE of moisture!
Ingress of moisture will result in damage to
the alarm switchgear. During storage, observe
the permissible humidity and ensure the alarm
switchgear is stored so it is overflow-proof.
• The alarm switchgear must be protected from
direct sunlight, heat and dust. Heat or dust can
cause damage to electrical components!
• Following an extended period of storage, the
alarm switchgear should be dusted before com-
missioning.