Oil burner
TECHNICAL FEATURES
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
For use on hot air generator the burner must be fitted with control box type 479SE or 539SE.
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
CE Certification No. : 0036 0259/99 as 92/42/EEC.
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pressure regulator, 2
5 – Vacuum gauge connection
6 – Hydraulic jacks with air-damper
7 – Combustion head adjustment screw
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
10 – Regulation pressure, 1
11 – Economizer
1718
G20 I
CODE
71 / 95 – 240 kW
Gas oil, max. viscosity at 20 ° C: 6 mm
Single phase, 230 V ± 10%
Run current 1.5 A – 2750 rpm – 288 rad/s
5 m F
Secondary 8 kV – 16 mA
Pressure: 7 – 15 bar
0.33 kW
S7351
nd
stage
st
stage
3748410
–
6 / 8 – 20 kg/h
~
Fig. 1
EQUIPMENT
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
4
Screws and nuts for flange
1
Hinge
1
Screw with two nuts for flange
1
External probe
1
7 pin plug
1
4 pin plug
1
GB
484T1
TYPE
/s (1.5 ° E)
2
50Hz
Description