technical Data
site circular saw
Art. No ................................................................................75771
Service connection ..................................400 V~50 Hz
Rated input............................................3000W S6/40%
Idle speed .......................................................2800 min
Saw blade dia. x hole dia ............................500 x 30 mm
Riving knife ............................................................. 3 mm
Riving knife guide slot ...................................10,5 mm
Cutting depth max. ..........................................175 mm
The values stated are emission values and as such do not necessarily constitute values which are safe for the
2)
workplace. Al- though there is a correlation between emission levels and environmental impact levels, whether
further precautions are neces- sary cannot be derived from this. Factors influencing the actually present envi-
ronmental impact level in the workplace include the characteristics of the work area and other noise sources, i.e.
the number of machines and other neighbouring work process- es. The permitted workplace values can likewise
vary from country to country. This information is intended to assist the user in estimating hazards and risks.
The appliance meets EN 61000-3-11 requirements and is subject to special connection conditions. That means
that use on optionally selected connection points is inadmissible. The appliance can lead to occasional voltage
fluctuations under unfavourable power conditions. The appliance is only designated to be used for connection
points not exceeding the maximum allowed impedance of Zmax = 0,233 Ω. As a user, you must make sure your
connection point on which you want to use the appliance meets the above-mentioned requirements – after
agreement with your electricity supplier if necessary.
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
specified conditions Of use
The circular saw is only intended to cut wood and wood
like products. Respecting technical data and safety
precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
Residual risks
Danger of injury !
Always keep hands away from the path of the saw blade.
In spite of compliance with all relevant design
regulations, dangers may still present themselves
when the machine is operated, e.g.:
- work piece parts being thrown off,
- parts of damaged tools being thrown off,
- noise emissions,
- wood dust emissions.
Table Extension ......................................720 x 400 mm
Weight ......................................................................110 kg
Noise and Vibration information
Sound pressure level L
Guaranteed sound power level L
-1
Wear ear protectors!
Measured according to EN ISO 11202:1995/AC:1997,
1)
unter Last, Uncertainty K=4 dB (A)
emergency procedure
Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. For the sake of eventual
accident, in accordance with DIN 13164, a workplace
has to be fitted with a first-aid kit. It is essential to
replace any used material in the first-aid kit immedia-
tely after it has been used.
If you seek help, state the following pieces of infor-
mation:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
Requirements for operating staff 
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
Qualification:  Apart from the detailed instructions by
a professional, no special qualification is necessary
for appliance using.
Minimum age:  Persons over 18 years of age can
only work on the appliance. An exception includes
youngsters trained in order to reach knowledge
under supervision of the trainer during occupational
education.
eNGLish
................................87,6 dB (A)
1), 2)
pA
...............108 dB (A)
2)
WA
21