Technical Data
Submersiblesewagepump GS 4003 P
Art. No .................................................................................94638
Service connection ................................. 230 V/ 50 Hz
Motor output P1 ...................................................400 W
Max. immersion .........................................................7 m
Max. head of delivery .......................................... 5,5 m
Max. delivered quantity .................................8000 l/h
Max. suction ......................................................... 25 mm
Max. Water temperature .......................................35°C
Hose connection ................................................... 1 ¼" IG
Degree of protection ............................................ IP X8
IPX8
Weight ....................................................................3,25 kg
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specified Conditions Of Use
The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Power tool description
1 | Floating switch
2 | Suction foot
3 | Pump connection
4 | Pump connection angle
5 | Connecting branch for the hose fitted
6 | Handle
7 | Power supply cable
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Requirements for operating staff
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
Qualification : Apart from the detailed instructions
by a professional, no special qualification is necessary
for appliance using.
Minimum age : Persons over 16 years of age can
only work on the appliance. An exception includes
youngsters trained in order to reach knowledge
under supervision of the trainer during occupational
education.
Training : Using the appliance only requires corre-
sponding training by a professional or the Operating
Instructions. No special training is necessary.
The operator is responsible for accidents or risks to
third parties.
Observe to keep out of dangerous zone