• A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
• Only connect unit to a permanently
wired electrical installation with NYM-O/
NYM-J (0.75 mm² to 1.5 mm²) cables.
• The units may only be operated using
the voltage and frequency shown on the
rating plate.
• Perform the electrical connection in
accordance with the wiring diagram in
chapter
• The degree of protection stated on the
rating plate is only guaranteed if instal-
lation is undertaken correctly and if the
connecting cable is correctly guided into
the unit.
• Unit may also be energized when at a
standstill.
• Once maintenance and repair work is
complete, test the function.
● Exercise caution when handling packaging
materials. Observe applicable safety and
accident prevention requirements. Store
packaging material out of the reach of
children (risk of suffocation