7. PROGRAMMING

7.7.11 Start Speed in Open and Close Directions

Start Speed function allows switching the Soft-Start in OPEN and CLOSE directi-
ons ON and OFF.
deactivated (Default)
Soft Start active: motor will accelerate gradually until it reaches
standard speed.
Hard Start active, motor will start at the regular Speed and for the
first second the force sensor will not be considered.

7.7.13 Password Protected Functions and Setup

7.7.13a Password Setup
Learning Phase must be completed and Password must be set before doing chan-
ges for Password protected functions, like Force and Speed.
Chose the „PS" function to program password.
NOTE: "00" cannot be used as password. It is only used as a default setting.
Functions protected by password can't be accessed if the new password is not set.
Password will be required to change protected Functions after the setup.
Password Setup Procedure
1. Choose "PS" function and press "P" button.
2. "00" flashes on display.
3. Use "+" and "–" buttons to set the new password.
4. Press "P" button.
5. New set password value remains on display for 2 seconds. Then display
changes to "PS".
Please note your password where it can be found later.
7.7.13b Password Use
1. Choose "PS" function and press "P" button.
2. "00" flashes on display.
3. Use "+" and "–" buttons to enter the correct password and press "P" button to
confirm.
4. If correct password is entered, the display shows the value for 2 seconds and
changes to "PS".
5. Choose the protected function to set.
NOTE: If entered password is not correct, "00" will flash for 5 seconds, then
change to "PS". Use correct password to access protected Functions.
Attention: The password protected Advanced Settings can only be executed by a
trained professional. The requirements of the EU: EN 12453, EN 13241; GB (UK,
NI) BS EN 12453, BS EN 13241 must be fulfilled.
No password selected (Default)
Selection available

7.7.12 Maintenance Counter

Maintenance Counter function allows to set maintenance interval in cycles.
4 seconds pre-flashing of the Flashing Lamp will be a signal the interval is reached.
If PF Function (Pre-Flashing) is active then 4 second pre-flashing will be added
to the set time. To reset counter after maintenance is done, it will be enough to
program the cycles one more time.
no counter (Default)
1000 cycles
ATTENTION
Any changes done to the Password protected functions (Force and Speed)
require verification of speed and force according to EU: EN 12453, EN 60335-
2-103; GB (UK, NI) BS EN 12453, BS EN 60335-2-103.
S
S
S
S
S
S
15
2000 cycles
...
... cycles
20000 cycles
P
+
P
+
P
+
P
+
P
+
P
+
2 sec.
2 sec.