Wing Movement Direction; Basic Settings; Application Settings; Direction Motor Settings - LiftMaster myQ SL400EVK Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. PROGRAMMING

7.3 Wing Movement Direction

Before programming, move the gate manually in the middle position and re-engage
release mechanism (see page 6). Press and hold the "–" button on the control
board and ensure that the motor is moving in CLOSE direction. If correct, immedia-
tely let go of the "-" button and gate stops.
If motor is moving in OPEN direction, go to the functions "d1" and change the
direction settings.
Once CLOSE direction is set correctly, leave the gate in the middle position. The
operator is ready for the Learning phase.
Note: gate can be moved with "+" and "-" buttons prior to final settings if required.
Press and hold the "+" button on the control board to move the gate into OPEN
position. When button is released operator stops.
Press and hold the "–" button on the control board to move the gate into CLOSE
position. When button is released operator stops.

7.4 Basic Settings

Basic Settings Overview
LED
AP
Application
d1
Direction Motor 1
LL
Limit Learning Phase

7.4.1 Application Settings

Application function shown on display.
This function is already pre-set at factory at correct value as defined for
the delivered operator.
Sliding gate, SL400
Sliding gate, SL600
Sliding gate, SL1000
More settings available on demand:
No application selected
Values 04, 05, 06 and 07 are not suitable for SL application and shall not be chosen

7.4.2 Direction Motor Settings

Direction Motor function shown on display
Defines movement direction of the Motor.
Motor is installed on left hand side (default).
Motor is installed on right hand side.
Function
Basic Settings (mandatory)

7.4.3 Limit Learning

Before Limit Learning Phase can be started the preparation for the learning
of the end limit position must be done as described in the section Limit
switch position Set up.
Assure that the Limit positions are checked and the door is in the the middle
position to start the Limit Learning Learning Phase.
Before starting a Learning phase ensure that:
1. Other Basic Settings are completed
2. Magnets are installed and working correctly
3. First movement will be in CLOSE direction.
Available Learning methods:
Standard Learning Mode (Automatic)
1. OPEN the LL menu.
2. Press and hold "+ and –" buttons for 2 seconds.
3. Automatic learning process starts. LL will flash on the display during complete-
process.
4. Gate moves in CLOSE direction until the CLOSE limit switch is reached, and-
stops for 2 seconds., then moves in the OPEN direction.
5. Gate moves in OPEN direction until the open limit switch is reached.
6. Gate moves in CLOSE direction until the close limit switch is reached, and-
stops.
7. Standard Learning phase is finished. LL will appear on display and board will
return in stand-by mode after 3 seconds.
S
P
Following settings are done during Standard Learning Mode:
1. Travel length from FULL CLOSED to FULL OPEN position.
2. Opening and closing force.
3. 60 cm of travel travel in both directions is assigned for Soft Stop.
10
+
2 sec.
3 sec.