Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. PROGRAMMING
Advanced Learning Mode (manual setting of Soft Stop position)
Advanced Learning Mode (manual setting of Soft Stop)
1. Open LL Menu.
2. Press and hold "+ and –" buttons for 2 seconds. Automatic learning starts, LL
will flash on the display during the complete process.
3. Gate moves in CLOSE direction up to the close limit switch is reached, and
stop for 2 seconds, then moves in the OPEN direction.
4. To define start of the Soft Stop in OPEN direction press "P" button at required
start point. Gate will continue opening until limit switch is reached, stops for 2
seconds, then moves in CLOSE direction.
5. To define start of the Soft Stop in CLOSE direction press "P" button at required
start point. Gate will continue closing until limit switch is reached, then stops.
6. Advanced learning phase is finished, LL will appear on the display and board
will return in stand by mode after 3 sec.
Following settings are done during Advanced Learning Mode:
- Travel length from FULL CLOSED to FULL OPEN position.
- Opening and closing force.
- Starting position of the Soft Stop.
NOTE: To stop Learning phase press "S" button. The Learning process will be
interrupted, "LE" will flash on LED display. After 5 seconds "LL" will appear on
display indicating readiness to start Learning phase again.
If Learning process was not completed, it needs to be re-done.
ATTENTION: Learning phase must be completed to enable operation.

7.5 Stand-by Mode

After the control board is powered on and programming is finished, the LED display
lights completely for 2 seconds and goes into the stand-by mode. During Stand-by
mode the LED display shows current gate status.
Motor is opening, upper section of the display flashes.
Motor stops at the opening position on the limit switch, upper
section of the display is on.
Motor is closing, lower section of the display flashes.
Motor stops at the closed position on the limit switch, lower
section of the display is on.
Motor stops in the middle, middle of the display is on.
Herewith the Basic Settings are completed. You can leave Programming
and operate your gate or proceed with Advanced Settings.
S
P
S
P
S
One motor
11
S
P
+
2 sec.
+
Soft Stop OPEN
Gate
+
Soft Stop CLOSE
Gate
P
+
3 sec.
5 sec.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Myq sl600evkMyq sl1000evk

Table des Matières